The HRV must be located in a heated space where it will be
possible to conveniently service the unit. Typically the HRV
would be located in the mechanical room or an area close to the
outside wall where the weather hoods will be mounted. If a
basement area is not convenient or does not exist, a utility or
laundry room may be used.
Attic installations are not normally recommended due to:
A) the complexity of work to install
B) freezing conditions in the attic
C) difficulty of access for servicing
Suspending the HRV
The hanging straps should be attached to the unit at the top end
corners (mounting screws are already located on the HRV case).
Securely fasten the other end of the straps to the floor joists with
wide head nails (not supplied), making sure the UNIT IS
LEVEL. The straps are designed to reduce the possibility of
noise, resonance or harmonics; therefore using the full length of
the strap between the HRV and the floor joists is recommended.
Wide Head Nails 
(not supplied)
STRAPS 
AND 
SCREWS 
(supplied)
WIDE HEAD 
NAILS
(not supplied)
DETAIL
*NOTE: 
Front clearance of 
25 inches (635 mm)  
is recommended 
for ser vicing unit.
19"
(483)
14 3/4"
(375)
31"
(787)
Suspending the HRV using the
Provided Hanging Straps
Unit must be installed level to ensure proper 
condensate drainage.  Due to the broad range of 
installation and operational conditions, 
consideration must be given for the possibility 
of condensation forming on the unit or 
connecting ducting.  Objects below the 
installation may be exposed to condensate.
CAUTION
Locating and Suspending the HRV
Improper installation, adjustment, alteration, 
service or maintenance can cause property 
damage, personal injury or loss of life.  
Installation and service must be performed by a 
qualified installer or service agency.
WARNING
Electric shock hazard.  Can cause 
injury or death.  Before attempting to 
perform any service or maintenance, 
turn the electrical power to unit OFF 
at disconnect switch(es).  Unit may 
have multiple power supplies.
WARNING
All models except the RNC120D are designed for horizontal
installation only as shown.
Using full length hanger straps is recommended for vibration
control, but can be shorter if required.
A minimum of 25" (635mm clearance is recommended so the
door can be opened.