Viking F20470I EN Installationsanweisungen

Seite von 24
23
22
* A 1,200 CFM interior- or exterior-power ventilator should be used when installed over range/rangetop with gas char-grill.
Max duct run is 50 ft.
** It is recommended that the 1,500 CFM ventilator be used with longer duct runs. Max duct run is 75 ft.
NOTE: Maximum amp rating for hoods includes recommended ventilator kit rating; All products must be hard wired with 2-
wire with ground. An interior or exterior-power ventilator kit must be purchased for installation with all 18”H. hoods.
Dimensions & Specifications
Clearance Dimensions
(VCIH Chimney Island Hoods) 
NOTE: Optional duct cover sold separately.
(VCIH Chimney Island Hoods 36”, 42”, 54”, & 66”) 
VCIH Chimney Island Hoods
Description
36”
42”
54”
66”
Duct cover width
12” (30.5 cm)
12” (30.5 cm)
18” (45.7 cm)
24” (70.0 cm)
Duct cover depth
12” (30.5 cm)
Duct cover height
12” (30.5 cm) or 24” (61.0 cm) or 36” (91.4 cm)
Number of lights
4
4
6
8
Number of filters
4
4
6
8
Heat lamps
N/A
Interior ventilator kits
VINV600
VINV600
VINV1200*
VINV1200*
Exterior ventilator kits
DEV900/1200*
DEV900/1200*/1500**
DEV1200*/1500**
DEV1200*/1500**
In-line ventilator kits
DIL900/1200
DIL900/1200
DIL1200
DIL1200
Interior duct size
7” (17.8 cm)
7” (17.8 cm)
10” (25.4 cm)
10” (25.4 cm)
Exterior duct size
10” (25.4 cm)
Interior—Maximum amps
4.6
4.6
8.9
9.3
Exterior—Maximum amps
7.4/4.7
7.4/4.7/5.5
5.6/6.4
6.4/7.4
In-Line—Maximum amps
4.7/6.5
3.9/5.7
7.4
7.4