26
Dimensions & Specifications
(VBCV Wall Custom Ventilator System 30”, 36”, 42”, 48”, 54”, 60” & 66”)
* A 1,200 CFM interior- or exterior-power ventilator should be used when installed over range/rangetop with gas char-grill.
Max duct run is 50 ft.
** It is recommended that the 1,500 CFM ventilator be used with longer duct runs. Max duct run is 75 ft.
NOTE: Maximum amp rating for hoods includes recommended ventilator kit rating; All products must be hard wired with 2-
wire with ground. An interior- or exterior-power ventilator kit must be purchased for installation with all 18”H. hoods.
Bottom Cutout Dimensions
*For best results,
center the unit over
the burners of the
cooking product
(front to back; right
to left).
Wall Hoods
Description
A (Hood Width)
B (Hood Depth)
30” W.
27-7/16” (69.7 cm)
21-7/16” (54.5 cm)
36” W.
33-7/16” (84.9 cm)
21-7/16” (54.5 cm)
42” W.
39-7/16” (100.2 cm)
21-7/16” (54.5 cm)
48” W.
45-7/16” (115.4 cm)
21-7/16” (54.5 cm)
54” W.
51-7/16” (130.7 cm)
21-7/16” (54.5 cm)
60” W.
57-7/16” (145.9 cm)
21-7/16” (54.5 cm)
66” W. 
63-7/16” (161.1 cm)
21-7/16” (54.5 cm)
Make sure the back wall
of the custom hood
canopy is flush with the
cutout so the ventilator
system may be mounted
as shown on page 25.
Installing Hood Canopy
Custom Hood
Canopy
1)  Position ventilator
system inside of the
custom hood canopy
and center it front to
back and left to right.
2)  Bottom mounting holes
fasten ventilator system
to bottom of custom
hood canopy with the
screws provided.
Built-In Ventilator
System
3) OPTIONAL
Rear mounting holes fasten
ventilator system to rear of
custom hood canopy.
(Custom Hood Canopy Cutouts
)
VBCV Wall Custom Ventilator System
Description
30”
36”
42”
48”
54”
60”
66”
Number of lights
2
2
2
3
3
4
4
Number of filters
2
2
2
3
3
4
4
Heat lamps
1
1
1
2
2
2
2
Interior ventilator kits
VINV300/
600/1200*
VINV300/
600/1200*
VINV600/
1200*
VINV1200* VINV1200* VINV1200* VINV1200*
Exterior ventilator kits
DEV900/
1200*
DEV900/
1200*
DEV900/
1200*
DEV1200*/
1500**
DEV1200*/
1500**
DEV1200*/
1500**
DEV1200*/
1500**
In-line ventilator kits
DIL900/1200
DIL900/1200 DIL900/1200
DIL1200
DIL1200
DIL1200
DIL1200
Interior duct size
7”/10”
(17.8/25.4 cm)
7”/10”
(17.8/25.4 cm)
7”/10”
(17.8/25.4 cm)
10”
(25.4 cm)
10”
(25.4 cm)
10”
(25.4 cm)
10”
(25.4 cm)
Exterior duct size
10” (25.4 cm)
Interior—Maximum amps
5.9/9.0
5.9/9.0
5.9/9.0
11.5
11.5
11.9
11.9
Exterior—Maximum amps
8.7/6.0
8.7/6.0
8.7/6.0
8.5/9.2
8.5/9.2
8.9/9.2
8.9/9.2
In-Line—Maximum amps
6.0/7.9
6.0/7.9
6.0/7.9
10.3
10.3
10.7
10.7