Routine Maintenance
Replace the Fuse
1/7/10
Xi4™/RXi4™ User Guide
P1009874-002
Replace the Fuse
The instructions that follow are for the 140Xi4, 170Xi4, and 220Xi4 printers only. Fuses are 
not user-replaceable in the 110Xi4.
The printer uses a metric-style fuse (5 × 20 mm IEC) rated at F5A, 250 V. The AC power entry 
module comes with two approved fuses in the fuse holder: one is in-circuit, and the second is 
provided as a spare. The end caps of the fuse must bear the certification mark of a known 
international safety organization (see 
To replace a faulty fuse, complete these steps:
1.
2.
Use a small-blade screwdriver or similar tool to remove the fuse holder. 
The fuse holder is part of the AC power entry module at the rear of the printer (
).
Figure 21 • AC Power Entry Module
3.
Remove the faulty fuse and install a new fuse in the in-circuit position (
Caution • 
Turn the AC power switch off (O) and remove the power cord before performing 
this procedure.
Caution • 
Turn off (
O
) the printer and disconnect it from the power source before 
performing the following procedure.
Turn off (O) the printer, and disconnect the AC power cord and all data cables.
1
Power switch
2
Fuse holder
3
AC power entry module
4
Small-blade screwdriver
Important • 
 If you use the spare fuse, be sure to order a replacement fuse from an 
authorized Zebra distributor. The spare fuse should be the exact type and rating as the 
original in-circuit fuse.
1
2
3
4