Replace the Fuse
The instructions that follow are for the 140Xi4, 170Xi4, and 220Xi4 printers only. Fuses are
not user-replaceable in the 110Xi4.
not user-replaceable in the 110Xi4.
The printer uses a metric-style fuse (5 × 20 mm IEC) rated at F5A, 250 V. The AC power entry
module comes with two approved fuses in the fuse holder: one is in-circuit, and the second is
provided as a spare. The end caps of the fuse must bear the certification mark of a known
international safety organization (see
module comes with two approved fuses in the fuse holder: one is in-circuit, and the second is
provided as a spare. The end caps of the fuse must bear the certification mark of a known
international safety organization (see
To replace a faulty fuse, complete these steps:
1.
2.
Use a small-blade screwdriver or similar tool to remove the fuse holder.
The fuse holder is part of the AC power entry module at the rear of the printer (
).
Figure 21 • AC Power Entry Module
3.
Remove the faulty fuse and install a new fuse in the in-circuit position (
Caution •
Turn the AC power switch off (O) and remove the power cord before performing
this procedure.
Caution •
Turn off (
O
) the printer and disconnect it from the power source before
performing the following procedure.
Turn off (O) the printer, and disconnect the AC power cord and all data cables.
1
Power switch
2
Fuse holder
3
AC power entry module
4
Small-blade screwdriver
Important •
If you use the spare fuse, be sure to order a replacement fuse from an
authorized Zebra distributor. The spare fuse should be the exact type and rating as the
original in-circuit fuse.
original in-circuit fuse.