Optional Top Vent Application
The DVBR36/42 fireplace is shipped as a rear vent unit. 
If the layout requires a top vent, convert the unit follow-
ing the steps below.
DVBR36
1.  Remove the eight (8) screws securing outer collar 
adapter to fireplace. (Be careful not to damage insu-
lation.) (Fig. 10)
2.  Set outer collar adapter aside.
DVT584-602
Outer Collar Adapter
Flue Pipe
3/11/99   djt
Flue Pipe
Remove 
Screws (4)
Outer Collar 
Adapter
Remove Screws (4)
DVT584-602
Rear View
Fig. 10  Remove screws from outer collar adapter.
6.  Secure flue cover to back of flue outlet. Be sure to 
replace gasket. (Fig. 12)
7.  Install flue pipe to top of unit with four (4) screws. Be 
sure to replace gasket. (Fig. 12)
8.  Set insulation in back of unit foil side down.
9.  Secure outer collar adapter to unit with the round 
collar on top, secure with eight (8) screws.
NOTE: Be sure not to damage any gasket material.
3.  Remove insulation on top of collector box. (Fig. 11)
4.  Remove the four (4) screws securing flue cover to 
top of unit and remove flue cover. (Fig. 11)
5.  Remove the four (4) screws securing flue pipe to 
back of unit. Remove flue pipe. (Fig. 11)
DVT584-603
Outer Collar Adapter
Flue Pipe
3/11/99   djt
Insulation
Remove 
Screws (4)
Remove Screws 
(4)
Flue 
Cover
Flue 
Pipe
DVT584-603
Fig. 11 Remove flue cover and flue pipe.
DVT584-604
Outer Collar Adapter
Flue Pipe
3/11/99   djt
Flue 
Pipe
Foil Side
Replace 
Screws 
(4)
Insulation
Flue Pipe
DVT584-604
Fig. 12 Replace flue cover and flue pipe.
Replace 
Screws (4)
DVT584-605
Outer Collar Adapter
Flue Pipe completed
3/11/99   djt
DVT584-605
Fig. 13  Completed conversion.