Broan EW5636SS Benutzerhandbuch

Seite von 28
MODELS  EW5630SS • EW5636SS
Page 3
INSTALL THE WIRING
INSTALL THE HOOD MOUNTING 
SUPPORT
1.  Construct  wood  wall  framing  that  is  flush  with  interior
surface of wall studs. Make sure the framing is centered over
installation location.
NOTE
Hood distance above cooktop is: Minimum 24”, Maximum 36”.
9-ft.  and  10-ft.  ceilings  may  require  Flue  Extension,  Model
FXNE56SS  depending  on  installation  height  (purchase
separately). See chart below for additional installation height
information.
2.  After wall surface is finished, fasten (2) 4mm x 38mm screws
at the locations shown above. DO NOT TIGHTEN screws all
the way.
12”
MAX.
HOOD
CENTERLINE
5”
MAX.
15¼”
24” TO 36”
ABOVE COOKT
OP
GROUNDING INSTRUCTIONS
This appliance must be grounded. In the event of an electrical
short  circuit,  grounding  reduces  the  risk  of  electric  shock  by
providing an escape wire for the electric current. This appliance
is equipped with a cord having a grounding wire with a grounding
plug. The  plug  must  be  plugged  into  an  outlet  that  is  properly
installed and grounded.
Position  the  electrical  outlet  within  the  space  covered  by  the
decorative  flue  and  where  it  will  not  interfere  with  the  round
duct.  Make  sure  the  outlet  is  no  further  than  12”  from  the  top
of the hood chassis and that the outlet does not interfere with
a mounting bracket fastening area or where the decorative flue
touches the wall.
C
L
36” HIGH COOKTOP
13 
7
/
3 ”
7
/
16 
4mm x 38mm
SCREWS
HERE
A
SEE
CHART
BELOW
24"
25"
26"
27"
28"
29"
30"
31"
32"
33"
34"
35"
36"
Ceiling
Height
8 Feet
39-7/8"
40-7/8"
41-7/8"
42-7/8"
43-7/8"
44-7/8"
45-7/8"
46-7/8"
47-7/8"
48-7/8"
*49-7/8"
*50-7/8"
*51-7/8"
9 Feet
**46-7/8"
**47-7/8"
**48-7/8"
49-7/8"
50-7/8"
51-7/8"
9 Feet 
with
FXNE56SS
39-7/8"
40-7/8"
41-7/8"
42-7/8"
43-7/8"
44-7/8"
45-7/8"
10 Feet 
with
FXNE56SS
39-7/8"
40-7/8"
41-7/8"
42-7/8"
43-7/8"
44-7/8"
45-7/8"
46-7/8"
47-7/8"
48-7/8"
49-7/8"
50-7/8"
51-7/8"
* Not recommended for non-ducted configuration
** Non-duct recirculation louvers will be exposed in ducted configuration
Desired Hood Distance (Above 36" High Cooktop)
Upper Mounting Screws Location (Distance above 36" High Cooktop - 
(Dimension “A”)