Broan EW5636SS Benutzerhandbuch

Seite von 28
MODELS  EW5630SS • EW5636SS
Page 4
C
L
Flush with 
the ceiling
Center of 
installation
Upper flue mounting  
bracket slots
Ceiling
INSTALL THE HOOD 
(Ducted Hoods Only)
1.  Center the flue mounting bracket over the hood location and
flush  with  the  ceiling.  Secure  the  upper  flue  bracket  to  the
wall using (2) 4mm x 38mm mounting screws. Note: Drywall
anchors may be needed (not included).
2.  Tighten the screws completely. Make sure that the bracket is
tight against the wall and ceiling.
3.  Remove (3) screws holding electronics mounting bracket to
hood.  Rotate  bracket  180  degrees  and  re-attach  bracket  to
hood with same (3) screws.
4.  Remove  the  protective  plastic  film  covering  the  decorative
flue and the hood at this time.
5.  Remove the grease filter by pulling down the metal latch tab
and tilting filter downward to remove.
6.  Align the keyhole slots on the hood with the mounting screws
that were partially tightened into the wall framing. Ensure that
hood is seated entirely on mounting screws, and that hood is
level. Then tighten screws completely.
7.  Install (2) 4mm x 38mm long screws into the holes inside the
hood and tighten them securely.
8.  Carefully place glass canopy on top of the hood. Align nuts
on glass canopy with holes inside the hood. Attach canopy
with (4) .188” x .250” long flat head screws. Tighten screws
securely but DO NOT OVERTIGHTEN.
9.  Reinstall  grease  filter  by  aligning  side  filter  tab  with  slots
in  the  hood.  Pull  down  the  metal  latch  tab,  push  filter  into
position  and  release.  Make  sure  filter  is  securely  engaged
after installation.