Magnetek Quattro DC Elevator Drive Benutzerhandbuch
Quattro DC Display Data D0 Menu
Parameter Description
Units
Hidden
Item
RX COM STATUS
(continued)
(continued)
Bit Severity Name Description/Reason
7
Info
RX_INVALID_MONITOR_ID
(Not available in Mode 2)
(Not available in Mode 2)
Set if the Monitor_Id
received in the run message is not in range.
8 Info
RX_INVALID_FAULT_ID
Set if the Fault_Id sent in
the setup message is not in range.
9 Info
RX_FAULT_DETECTED
COMM FAULT has been
detected
10 Info
Fault_Mode_1
(Not available in Mode 1)
(Not available in Mode 1)
Immediate Shutdown
Mode
11 Info
Fault_Mode_2
(Not available in Mode 1)
Run Removal Shutdown Mode
(Not available in Mode 1)
Run Removal Shutdown Mode
12 Info
Fault_Mode_3
(Not available in Mode 1)
(Not available in Mode 1)
Rescue Shutdown Mode
13
N/a
14
N/a
15 Fatal
RX_COMM_FAULT
COMM FAULT has been
declared by the drive
1=true
0=false
N
LOGIC OUTPUTS
(Logic Outputs Status) This display shows the condition of the
logic outputs. (1=true 0=false)
logic outputs. (1=true 0=false)
1=true
0=false
N
LOGIC INPUTS
(Logic Inputs Status) This display shows the condition of the logic
inputs. (1=true 0=false)
inputs. (1=true 0=false)
1=true
0=false
N
Table 1 : Elevator Display Data D1 Submenu
3
RUN/FAULT
SUB MENU
DATA ENT
LOGIC OUTPUTS
D1 00000000000
Logic output 1
Logic output 7
Relay output 1
Relay output 2
Solid State Relay 1
Solid State Relay 2
RUN/FAULT
SUB MENU
DATA ENT
LOGIC INPUTS
D1 000000000
Logic Input 1
Logic Input 9
67