Quattro DC Display Data D0 Menu 
 
Parameter Description 
Units 
Hidden
Item 
RX COM STATUS 
(continued) 
Bit Severity  Name Description/Reason 
Info 
RX_INVALID_MONITOR_ID 
(Not available in Mode 2) 
Set if the Monitor_Id 
received in the run message is not in range. 
8 Info 
RX_INVALID_FAULT_ID
 Set if the Fault_Id sent in 
the setup message is not in range. 
9 Info 
RX_FAULT_DETECTED
 COMM FAULT has been 
detected 
10 Info 
Fault_Mode_1 
(Not available in Mode 1) 
Immediate Shutdown 
Mode 
11 Info 
Fault_Mode_2 
(Not available in Mode 1) 
Run Removal Shutdown Mode 
12 Info 
Fault_Mode_3 
(Not available in Mode 1)
 
Rescue Shutdown Mode 
13  
N/a 
14  
N/a 
15 Fatal 
RX_COMM_FAULT 
COMM FAULT has been 
declared by the drive  
 
1=true 
0=false 
LOGIC OUTPUTS 
(Logic Outputs Status) This display shows the condition of the 
logic outputs. (1=true 0=false) 
 
 
 
 
 
 
 
 
 
 
 
 
1=true 
0=false 
LOGIC INPUTS 
(Logic Inputs Status) This display shows the condition of the logic 
inputs. (1=true 0=false) 
 
 
 
 
 
 
 
 
 
1=true 
0=false 
Table 1 : Elevator Display Data D1 Submenu 
3
RUN/FAULT 
SUB MENU 
DATA ENT 
LOGIC OUTPUTS 
D1   00000000000
Logic output 1
Logic output 7
Relay output 1
Relay output 2 
Solid State Relay 1
Solid State Relay 2
RUN/FAULT 
SUB MENU 
DATA ENT 
LOGIC INPUTS 
D1 000000000
Logic Input 1
Logic Input 9