Bertazzoni A304GGVXE/02 Benutzerhandbuch

Seite von 46
 
16
 
GAS CONVERSION 
 
WARNING! 
Before carrying out this operation, disconnect 
the appliance from gas and electricity. 
Gas conversion shall be conducted by a factory‐
trained professional. 
Call the customer service hotline to identify a 
factory‐trained professional near your home. 
The gas conversion procedure for this range 
includes 6 steps: 
1. Pressure 
regulator 
2. Surface 
burners 
3.  Main oven burner 
4. Broiler 
burner 
5.  Visual checks prior to closure of oven bottom 
panel 
6.  Adjustment of minimum setting 
The conversion is not completed if all 6 steps 
have not been concluded properly. 
Before performing the gas conversion, locate the 
package containing the replacement nozzle 
shipped with every range. IMPORTANT: Each 
nozzle has a number indicating its flow diameter 
printed on the body. Consult the table on page 20 
for matching nozzles to burners. 
Save the nozzles removed from the range for 
future use.  
 
STEP 1: PRESSURE REGULATOR 
The pressure regulator supplied with the 
appliance is a convertible type pressure regulator 
for use with LP/Propane Gas at a nominal outlet 
pressure of 11” w.c. or LP gas at a nominal outlet 
pressure of 4” w.c. and it is pre‐arranged from 
the factory to operate with one of these 
gas/pressure as indicated in the labels affixed on 
the appliance, package and Instruction booklet. 
To convert the regulator for use with other 
Natural gas: 
1.  Unscrew by hand the upper cap of the 
regulator, remove the white plastic 
attachment from the cap, reverse its 
direction and screw it again firmly against the 
cap. The white plastic attachment has arrows 
indicating the position for LP gas (LP)and 
natural gas (NAT). 
2.  Screw by hand the metal cap in the original 
position on the regulator.