STEP 5: VISUAL CHECKS 
Before reinstalling the bottom panel, the 
following visual check must be performed to 
ensure that the conversion has been carried out 
properly and without damage to other 
components of the range. 
 
A) CONNECTION 
OF 
THERMOCOUPLES TO 
THERMOSTAT 
The thermocouples for both broiler and main 
oven burner are connected to the same magnet. 
Tight gently the two connections alternating 
action on the two nuts. Do not fully tighten one 
thermocouple before having started to tighten 
the second one. 
 
 
B)  OVEN IGNITER AND THERMOCOUPLE 
POSITION 
The appropriate gap between the tip of the spark 
plug or thermocouple and the burner shall be 
approximately 1/8’’. 
 
 
The tip of the spark plug or thermocouple must 
fully overlap at least the first gas emission hole of 
the burner. 
 
 
After performing all these visual checks, reinstall 
the bottom panel of the oven compartment and 
proceed to setting the minimum for each 
burner.