Russound CAM6.6T-S1 Benutzerhandbuch

Seite von 112
58
INSTALLER
INSTALLATION MENU
All settings including source equipment IR commands will need to
be reentered. An “Are you sure?” prompt and a “no” response 
allows the installer to cancel the reset; a “yes” at the prompt will 
load factory/default settings.
POWER MANAGEMENT (PwMgt)
The CAM6.6 is capable of managing the power state of the connected source equipment. The power
management is configured on a source-by-source basis. 
All sources that have power management enabled are initialized by a “POWER ON” command or
macro. Power management is initialized when the first keypad is turned on or when the home theater
trigger input has 12VDC present. The 12VDC trigger output is turned on when the first zone is turned
on.
All sources that have power management enabled are turned off by the “POWER OFF” command after
all zones have been turned off, with a timeout of five minutes.The 12VDC trigger output is turned off
one minute after that. This timeout is postponed for as long as the home theater trigger input has
12VDC present. 
See Power Management - Flow Chart on page 61
1. SOURCE NUM – 
Select the source number this feature will be configured for.
(Src #)
2. POWER ON CMD – 
Tells the controller to turn on the selected source equipment (by 
(OnCmd)
SOURCE NUMBER) when any of the UNO System Keypads is 
turned on. If “no,” procedure advances to POWER OFF CMD (step 6)
3. COMMAND TYPE – 
Select the type of source command (e.g., CD, TV, etc.). 
(CmdTp)
a. Selected: Learned IR 
Choose Learned IR if the pre-programmed IR code library does 
(LrnIR)
not support the source component.
i. LEARNED SRC – 
Select the learned source bank to be assigned to the source 
(LnSrc)
component. Procedure advances to KEY FUNCTION (step 5)
b. Selected: Unassigned
The Power On command is cleared. Procedure advances to 
(Unasg)
POWER OFF CMD (step 6)
c. Selected: Default
Default selects the same device type and device code previously
(Deflt) 
setup in BASIC SETUP. Procedure advances to KEY FUNCTION 
(step 5)
d. Selected: Macro:
(To build macros, see Macro Editor page 61)
(Macro)