Radiance Direct Vent Gas Heater 
20012697
Instructions for Comfort Control Valve
RADVTC Series
The Comfort Control valve allows remote control of 
temperature, fan and flame appearance.
NOTE: The antenna should hang in free air away from 
grounded metal.
Operation
1.  If the manual switch is in remote position, switch it to 
LOCAL. (Fig. 57)
2.  Turn the pilotstat knob counterclockwise from OFF 
to the PILOT position, push the knob down, and hold 
in position. The pilot valve opens and allows gas to 
flow to the pilot burner.
3.  Push plunger on the piezo until the pilot burner is lit. 
When the pilot burner is lit, the LED on the control 
will come on after approximately 40 seconds and 
will provide 1 short blink continuously in the normal 
mode. When the light turns off which will be approxi-
mately 10 seconds after it has been continuously 
red, the receiver/valve is fully powered.
4.  Release the knob. The shaft will move upward. The 
pilot burner should now stay burning. If the pilot 
burner goes out, repeat step 2.
5.  Turn the knob counterclockwise to the ON position. 
If the manual switch is in the LOCAL position, the 
main burner will turn on immediately.
6.  ON the initial use of a transmitter, a recognition 
operation is required between the receiver/valve 
and transmitter. Change the switch from LOCAL 
to REMOTE. Press the fan or flame button on the 
transmitter within 30 seconds. The LED will blink 
indicating the transmitter will now work with the re-
ceiver/valve. If the switch continues in the REMOTE 
position, the transmitter will now control the main 
valve, flame modulation level and fan control.
7.  If the manual switch is in the LOCAL position, the 
valve will be at the highest fixed pressure setting 
and the fan will be at the highest fixed speed. The 
transmitter will control the fan only.
Shut Off Procedure
If the manual switch is in the REMOTE position, the 
transmitter can shut off the main burner and fan. How-
ever, the control is still on and a command from the 
transmitter can turn on the main burner or fan.
To shut off the system, turn the pilotstat knob clockwise 
to the OFF position. This action closes the main gas 
and safety valves. The transmitter cannot turn on the 
main burner or fan.
Transmitter Operation
Off Mode
In the OFF mode, the fireplace flame and fan are 
off, the display will show OFF and displays the room 
temperature. If the receiver is in REMOTE mode, the 
fireplace will shut off.
On (Manual) Mode
In the ON mode, the room temperature, flame and fan 
levels will be shown. MANUAL will appear next to both 
the flame and fan icons.
When the control is in the ON mode, the flame and fan 
levels, and delay timer are changed with the up and 
down buttons. To change the flame level, press the 
flame button followed by an arrow key. To change the 
fan level, press the fan key followed by an arrow key. 
Pushing the arrow key once will change the level by 
one unit.
Delay Timer Mode
The shut off delay timer has a maximum of 2 hours and 
a minimum of zero minutes. To change the timer level, 
press the time key followed by an arrow key. Pushing 
the key once will change the timer by 10 minutes.
FP1039
comfort valve
transmitter
3/27/00   djt
Fig. 58  Transmitter diagram.
Display
 
Room Temperature
 
Set Temperature
 
Flame Height Level
 
Fan Speed Level
 
Countdown Timer
 
Low Battery
Flame
Up
 
Increases Flame 
 
Height, Fan Speed
 
Timer, or Set Point
Down
 
Decrease 
Flame, Fan 
Speed Timer 
or Set Point
Mode
 
Auto
 
On
 
Off
Countdown
Timer
Fan
FP1039
FP1037
Honeywell 
comfort valve
3/22/00   djt
LOCAL
REMOTE
ON •
PILOT OFF
LED
Piezo Ignitor
Local/Remote 
Switch
Pilotstat 
Knob
LED
FP1037
Fig. 57  Comfort control valve.
Antenna
Motor Top Cap
Plug