Radiance Direct Vent Gas Heater 
20012697
Light pilot burner
Set manual switch 
to local or remote
Release pilotstat 
knob.
Turn pilotstat knob 
from PILOT to ON.
If manual switch is 
set to LOCAL, did 
main burner light 
and fan turn on?
Turn pilotstat knob 
to PILOT to turn 
off main burner.
Turn pilotstat knob 
to OFF to turn 
valve completely 
off.
Comfort Control Valve System Sequence of Operation with Transmitter
Did the LED stop 
blinking?
Review LED fail-
ure analysis.
Five minute wait 
period
Cycle switch 
once and leave in 
remote. Press any 
key on transmit-
ter for recognition 
operation.
Local Path
Move switch from 
local to remote. 
Press any key on 
transmitter. Move 
switch back to 
local.
Yes
If the manual switch 
is set to REMOTE,
press the mode but-
ton to display “ON”.
does transmitter con-
trol the main burner 
and fan?
Does transmitter 
change levels of 
flame height, fan 
speed?
Set levels of flame 
height and fan to 
“0” to shut off main 
burner and fan.
Turn pilotstat knob 
to OFF to turn 
valve completely 
off.
On Path
Move switch from 
manual to remote. 
Press any key on 
transmitter. 
Yes
Yes
No
Choose Manual or 
Remote path. Set 
switch to manual or 
remote.
Yes
No