OPERATING INSTRUCTIONS
Figure 21 - Pilot 
 
TO TURN OFF GAS TO HEATER
 
 1.  Turn ON/OFF switch to OFF position.
 2.  Turn control knob clockwise
to OFF position to completely shut off the heater.
 3.  If applicable: Turn off all electric power to the heater.
Figure 22 - Control Cover Plate for Milli-Volt 
Hi/Lo Control 
Ignitor/Pilot Control
On/Off Switch
(Located on Side 
of Stove) 
 1.  STOP! Read the safety information label.
 2.  Make sure the manual shutoff valve is fully open.
 3.  This gas log set is equipped with an ignition device (piezo) which automatically lights the pilot. If piezo
ignitor does not light the pilot, refer to instructions for Match Lighting Instructions, page 23.
 4.  Turn gas control knob clockwise
to the OFF position, turn ON/OFF switch to OFF position.
 5.  Wait (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP!
Follow the instructions under What To Do If You Smell Gas, page 21.
 6.  From OFF position, turn the gas control knob counterclockwise
to IGN position. Push in
control knob for 5 seconds. NOTE: If you are running the heater for the first time, it may be 
necessary to press in the control knob for 30 seconds or longer to allow air to bleed out 
of the gas piping. 
 7.  With the control knob pushed in, push in and release the piezo ignitor button to light the pilot.
 8.  Continue pushing the control knob in for a further 10 seconds to prevent the flame detector from shutting
off the gas while the probe is warming up. Release the control knob.
 9.  Turn gas control knob counterclockwise
to the ON position.
10.  After the pilot has been lit for one minute, the burners can be turned on. Turn the ON/OFF switch to ON
position.
11.  If the gas logs will not operate, follow the instructions “To Turn Off Gas To Heater” below and call your
service technician or gas supplier.
 MILLI-VOLT 
CONTROL LIGHTING INSTRUCTIONS