INITIAL START–UP 
PMA–5/12 AND PMA–5/18 OWNER'S MANUAL 
 
NU–VU® FOOD SERVICE SYSTEMS 
MENOMINEE, MICHIGAN 49858 
page 8 
SALES FAX (906) 863-5889  •  SERVICE FAX (906) 863-6322 
(906) 863-4401 
 
INITIAL START-UP PROCEDURE 
 
A.  Make sure the INSTALLATION of the unit is complete and correct. Check the exterior of the unit. 
All cover panels must be in place (with the exception of the Outside Top), and the unit itself must be 
securely seated on a level surface. 
 B. 
Check 
the 
interior of the unit. All interior parts must be installed and securely fastened. Make sure 
the Door is fully closed and latched (the Oven Motor will not run if the main Door is not fully 
closed). YOU MUST REMOVE ALL PROTECTIVE TAPE PRIOR TO TURNING POWER 
ON.
 
 
C.  Engage the main power supply and set the Power Switch  to the ON position. The interior lights 
should come on and the Oven Blower Wheel  should begin to rotate in a counter-clockwise direction 
as viewed from the inside of the Oven. 
 
 
NOTE: The Oven Motor will not run if the Oven Door is not fully closed!  
 
D.  Set the Temperature Control  to 300
°. The Temperature Control Indicator Light  will illuminate and 
the Oven will begin to heat up. 
 
E.  Carefully remove the Outside Top and measure the amperage on the exposed power supply lines. 
Compare these readings to the label on the side of your unit. If the readings and label differ by any 
great amount turn the unit OFF and call the NU-VU
®
 Service Department immediately at (906) 863-
4401. Carefully reposition the Outside Top on the Oven and press it into place if the amp readings 
and label coincide. Be careful not to pull or pinch any wires while replacing the Outside Top. 
 
F.  Set each of the Timers  in turn from 15 to 30 seconds and allow them to count down (refer to the 
TIMER INSTRUCTIONS in the OPERATING GUIDE). An electronic Alarm  should sound at the 
end of each timed cycle. If a Timer or Alarm does not work please review the TIMER 
INSTRUCTIONS
 or refer to the TROUBLE–SHOOTING GUIDE. If you still have a problem call 
NU-VU
®
 at (906) 863-4401 and ask for our Service Department. Someone there will be glad to 
assist you in any way possible. 
 
 
NOTE. Press the Start-Stop key on the Timer to silence the Alarm earlier. 
 
G.  Place an accurate and reliable oven thermometer in the center of the Oven and allow the Oven to 
heat to 300
°. Compare the thermometer reading and the Temperature Control setting when the 
Temperature Control Indicator Light goes out. If they differ by less than 10
° the Oven is ready for 
use. If there is a difference of 10
° or more you may wish to adjust the Temperature Control. 
  Please 
call 
the 
NU-VU
®
 Service Department at (906) 863-4401 before attempting to adjust the 
Temperature Control!!! 
 
 
Your PMA-5/12 or PMA-5/18 should now be 
 