PMA–5/12 AND PMA–5/18 OWNER'S MANUAL 
RECEIPT AND INSTALLATION 
 
NU–VU® FOOD SERVICE SYSTEMS 
MENOMINEE, MICHIGAN 49858 
(906) 863-4401 
SALES FAX (906) 863-5889  •  SERVICE FAX (906) 863-6322 
page 7 
INSTALLATION: 
 
A.  Check to determine that the power source is the same voltage and phase as that indicated on the label 
on the side of the unit. 
 
B.  Position the unit where it is to be operated and adjust the unit so that it stands level and solid. 
Remove the glass Light Globes from the rear wall of the Oven and install the included 40-watt 
Appliance Bulbs. Replace the glass Light Globes and close the Oven Door securely. 
 
C.  Carefully set all Controls and Switches to the OFF position. 
 
D.  The installing technician or electrician should remove the Outside Top of the unit (this panel is only 
pressed onto the top of the unit and should lift off easily). Connect the unit to the available power 
supply either through an attached cord and receptacle or through direct wiring by following these 
steps: 
 
 
1. 
Take note of the labeling on the Power Terminal Block (Line 1Line 2Line 3). 
 
 
2.  Carefully identify the power source leads and attach them to the appropriate terminal 
connections. 
 
 
3. 
Properly ground the unit BEFORE USE by attaching a grounding wire to the Ground Lug or 
Clamp provided next to the Power Terminal Block. 
4.  Allow enough slack in the wiring to allow for equipment to be moved about during installation 
and any future servicing. 
 
 
E.  Check the voltage at the terminals on the Power Terminal Block with a voltmeter and compare the 
values with the label listings on the side of the Oven. If the values match the unit is ready for its 
INITIAL START-UP. If the readings DO NOT coincide you must call the NU-VU
® 
Service 
Department. 
 
F.  Carefully position the Outside Top on the unit but do not press it into place. Position the unit in its 
final operating location and refer to the INITIAL START-UP PROCEDURE
 
 
IMPORTANT: DO NOT CONNECT THIS UNIT IF YOUR POWER SOURCE 
DOES NOT MATCH THE UNIT REQUIREMENTS!!! 
 
 
 
IMPORTANT: FAULTY INSTALLATION, IMPROPER USE, OR ANY OTHER 
FAILURE TO FOLLOW THESE INSTRUCTIONS MAY RESULT IN SEVERE 
EQUIPMENT DAMAGE OR PERSONAL INJURY, AND MAY ALSO VOID 
 ALL OR PART OF YOUR NU-VU
®