TO TURN OFF GAS 
TO APPLIANCE
1.  Turn off the wall switch.
2.  Turn off all electric power to the appliance 
if service is to be performed.
3.  Remove control access panel.
4.  Push in gas control knob and turn clockwise 
 to “OFF”. Do not force.
5.  Replace control access panel.
OPERATING FIREPLACE
Continued
Figure 24 - Pilot
Thermopile
Pilot 
Burner
Ignitor
ELECTRONIC MODELS
FOR YOUR SAFETY 
READ BEFORE LIGHTING
 WARNING: If you do not fol-
low these instructions exactly,
a  fire  or  explosion  may  result
causing property damage, per-
sonal injury or loss of life.
A.  This appliance has a pilot which must be 
lighted by hand. When lighting the pilot, 
follow these instructions exactly.
B.  BEFORE LIGHTING smell all around the 
appliance area for gas. Be sure to smell next 
to the floor because some gas is heavier than 
air and will settle on the floor.
 
WHAT TO DO IF YOU SMELL GAS
•  Do not try to light any appliance.
•  Do not touch any electric switch; do not 
use any phone in your building.
•  Immediately call your gas supplier from 
a neighbor’s phone. Follow the gas sup-
plier’s instructions.
•  If you cannot reach your gas supplier, 
call the fire department.
C.  Use only your hand to push in or turn the 
gas control knob. Never use tools. If the 
knob will not push in or turn by hand, don’t 
try to repair it, call a qualified service tech-
nician or gas supplier. Force or attempted 
repair may result in a fire or explosion.
D.  Do not use this appliance if any part has 
been  under  water.  Immediately  call  a 
qualified service technician to inspect the 
appliance and to replace any part of the 
control system and any gas control which 
has been under water.
LIGHTING 
INSTRUCTIONS
NOTICE: During initial operation 
of new heater, burning logs will
give off a paper-burning smell.
Orange flame will also be pres-
ent. Open window to vent smell.
This will only last a few hours.
1.  STOP!  Read  the  safety  information, 
column 1.
2.  Set the thermostat to lowest setting (if 
applicable).
3.  Turn off wall switch.
4.  Open control access panel or louver.
5.  Smell for gas, including near the floor. If you 
smell gas, STOP! Follow “B” in the safety 
information in column 1. If you don’t smell 
gas, go to the next step.
6.  Turn the main burner wall switch to the ON 
position for ignition. There will be a spark 
at the electrode.
7.  Replace control access panel or louver once 
there is a flame at the burner.
8.  If burner will not stay lit after several tries, 
flip the wall switch to OFF and call your 
service technician or gas supplier.
Figure 25 - Electronic Control Valve
E
A
From 
Gas 
Supply
To 
Main 
Burner
Inlet 
Pressure
Outlet 
Pressure