OPERATING FIREPLACE
MILLIVOLT MODELS
FOR YOUR SAFETY 
READ BEFORE LIGHTING
 WARNING: If you do not fol-
low these instructions exactly,
a  fire  or  explosion  may  result
causing property damage, per-
sonal injury or loss of life.
A.  This appliance has a pilot which must be 
lighted by hand. When lighting the pilot, 
follow these instructions exactly.
B.  BEFORE LIGHTING smell all around the 
appliance area for gas. Be sure to smell next 
to the floor because some gas is heavier than 
air and will settle on the floor.
 
WHAT TO DO IF YOU SMELL GAS
•  Do not try to light any appliance.
•  Do not touch any electric switch; do not 
use any phone in your building.
•  Immediately call your gas supplier from 
a neighbor’s phone. Follow the gas sup-
plier’s instructions.
•  If you cannot reach your gas supplier, 
call the fire department.
C.  Use only your hand to push in or turn the 
gas control knob. Never use tools. If the 
knob will not push in or turn by hand, don’t 
try to repair it, call a qualified service tech-
nician or gas supplier. Force or attempted 
repair may result in a fire or explosion.
D.  Do not use this appliance if any part has 
been  under  water.  Immediately  call  a 
qualified service technician to inspect the 
appliance and to replace any part of the 
control system and any gas control which 
has been under water.
LIGHTING 
INSTRUCTIONS
NOTICE: During initial operation 
of new heater, burning logs will
give off a paper-burning smell.
Orange flame will also be pres-
ent. Open window to vent smell.
This will only last a few hours.
1.  STOP!  Read  the  safety  information, 
column 1.
2.  Turn wall switch to the OFF position.
3.  Turn off all electric power to the appliance.
4.  Open control access panel.
5.  Push in gas  control knob and turn clock-
wise 
  to  the  OFF  position  (see 
Figure 23). Note: It is recommended that 
you maintain the gas control knob in the 
full OFF position during lengthy periods 
of seasonal non usage.
6.  Wait five (5) minutes to clear out any gas. 
Then smell for gas, including near the floor. 
If you smell gas, STOP! Follow “B” in the 
safety information above. If you don’t smell 
gas, go to the next step.
7.  Turn control knob counterclockwise 
 
to the PILOT position.
8.  Push in control knob all the way and hold 
in. Immediately light the pilot by pressing 
the  red  ignitor  button  until  a  flame  ap-
pears. Continue to hold the control knob 
in for about (1) minute after the pilot is lit. 
Release knob and it will pop back up. Pilot 
should remain lit. If it goes out, repeat steps 
5 through 8.
•  If knob does not pop up when released, 
stop and immediately call your service 
technician or gas supplier.
•  If the pilot will not stay lit after sev-
eral tries, turn the gas control knob to 
“OFF” and call your service technician 
or gas supplier.
9.  Turn  gas  control  knob  counterclockwise 
 to “ON”. Knob can be turned to 
“ON” only if the control knob is popped out.
10.  Replace control access panel.
11.  Turn on all electric power to the appliance.
Figure 23 - Millivolt Control Valve
Position Indicator
Gas Control Knob