Fireplace inSTallaTion
FRAMING
1.  Frame opening for fireplace using dimen-
sions shown in Figures 4 and 5.
2.  If  fireplace  is  to  be  installed  directly  on 
carpeting, tile (other than ceramic) or any 
combustible  material  other  than  wood 
flooring, fireplace must be installed upon 
a metal or wood panel extending full width 
and depth of fireplace.
3.  Set fireplace directly in front of this open-
ing and slide unit back until nailing flanges 
touch side framing.
4.  Check level of the fireplace and shim with 
sheet metal if necessary.
5.  Before  securing  fireplace  to  prepared 
framing, ember protector (provided) must 
be placed between hearth extension (not 
supplied) and under bottom front edge of 
fireplace to protect against glowing embers 
falling through. If fireplace is to be installed 
on a raised platform, a Z-type ember pro-
tector (not supplied) must be fabricated to 
fit  your  required  platform  height.  Ember 
protector should extend under fireplace a 
minimum of 1 
1
/
2
". Ember protector should 
be  made  of  galvanized  sheet  metal  (28 
gauge minimum to prevent corrosion.
6.  Using screws or nails, secure fireplace to 
framing through flanges located on sides 
of fireplace.
30.125"
59" (50" Models)
58.125"
67.125"
51.25" (42" Models)
45.25" (36" Models)
28.250" (36" Models)
Figure 4 - Framing Dimensions
71" (50" Models)
100" (50" Models)
65" (42" Models)
92" (42" Models)
86.5" (36" Models)
61" (36" Models)
Maintain 1 
1
/
2
"
Clearance 
at Sides and 
Back of Fireplace
1
/
2
" Clearance
Not Required at 
Nailing Flanges 
Figure 5 - Corner Installation
SELECTING LOCATION
To  determine  the  safest  and  most  efficient 
location for the fireplace, you must take into 
consideration the following guidelines:
1.  The location must allow for proper clear-
ances (see Figures 4 and 5).
2.  Consider a location where fireplace will 
not be affected by drafts, air conditioning 
ducts, windows or doors.
3.  A location that avoids cutting of joists or 
roof rafters will make installation easier.
4.  An  outside  air  kit  is  available  with  this 
fireplace (see Optional Outside Air Kit on 
page 8).
MINIMUM CLEARANCE TO 
COMBUSTIBLES
Back and sides of fireplace 
1
/
2
" min.*
Front of fireplace 
48" min.
Floor** 
0" min.
Perpendicular wall to opening 
18" min.
     36" Models 
12" min.
Top spacers 
0" min.
Mantel clearances 
see Mantels, page 7
Chimney outer pipe surface 
2" min.
     36" Model 
1" min. 
* Not required at nailing flanges
** See step 2 of Framing
 WARNING: Do not pack re-
quired air spaces with insulation 
or other materials.
Minimum/Maximum Chimney Height for 
Residential Installation
Minimum height of chimney, measured from 
base of fireplace to flue gas outlet of termina-
tion, is 16 feet for straight flue or a flue with 
one elbow set. Maximum distance between 
elbows is 6 feet. For systems with two elbow 
sets,  minimum  height  is  22  feet.  Maximum 
height of any system is 50 feet. This measure-
ment includes fireplace, chimney sections and 
height of termination assembly at level of the 
flue gas outlet (see Figure 15, page 11).