SYMPTOM
Burner fails to light
Burner  lights  but  goes  out 
when automatic control valve 
button is released
Maximum burn rate is low
TROUBLESHOOTINg
 WARNING: Never attempt to service heater while it is connected 
to propane/LP supply, operating, or hot. Severe burns can occur.
POSSIBLE CAUSE
1. Propane/LP  supply  valve 
closed on propane/LP cyl-
inder
2. Blockage  in  burner/orifice 
elbow/hose  and  regulator 
assembly
3. Battery not installed, battery 
power  low  or  battery  not 
installed correctly
1. Not enough warm up time
2. Low gas pressure
3. Thermocouple  loose  or 
needs to be replaced
4. Automatic  control  valve 
needs to be replaced
5. Thermocouple  gap  is  too 
great
1. Low gas pressure
2. Low fuel supply
3. Restriction in burner/orifice 
elbow/hose  and  regulator 
assembly
REMEDY
1. Open  propane/LP  supply 
valve slowly
2. Clean burner/replace orifice 
elbow/hose  and  regulator 
assembly
3. Install new alkaline battery 
in  electronic  ignitor.  Verify 
battery is installed correctly. 
See page 14
1. Relight,  hold  automatic 
control  valve  button  in  30 
seconds
2. Check propane/LP cylinder 
for proper gas supply
3. Tighten  connection  or  re-
place thermocouple
4. Replace automatic control 
valve assembly
5. Tip of thermocouple should 
just touch the emitter mate-
rial. Loosen bracket screws 
to move thermocouple clos-
er to burner. Be careful not 
to  allow  ignitor  to  touch. 
Maintain 0.20"
1. Check  gas  supply;  check 
regulator output
2. Consult  propane/LP  gas 
supplier
3. Clean burner/replace orifice 
elbow/hose  and  regulator 
assembly