SPECIFICATIONS
•  Rating: High - 16,000 Btu/Hr (4.69 kw)
   
Low - 9,500 Btu/Hr (2.78 kw)
•  Fuel: Propane Vapor Only
•  Fuel Consumption/Hour: Min. 0.10 gal (0.39 liter), Max. 0.17 gal (0.66 liter)
  Min. 0.44 lb (0.20 kg), Max 0.74 lb (0.33 kg) 
•  Supply Pressure (To Regulator): Maximum - 200 psi (1,379 Kpa)
  Minimum, for input adjustment - 5 psi (34.5 Kpa)
•  Manifold Pressure: High - 11 WC (2.74 kPa), Low - 10.6 psi (73.08 kPa)
•  Ignitor Gap: 0.120"
•  Minimum Temperature: -20°F (29°C) Surrounding Air Temperature
•  Heater Size (L x W x H): 30.5" x 30.5" x 43.5" (0.77 x 0.77 x 1.1 m)
•  Carton Size (L x W x H): 25.75" x 25.75" x 16.25" (0.65 x 0.65 x 0.41 m)
•  Heater Weight: 73 lb (33.1 kg)
•  Shipping Weight: 84 lb (38.1 kg)
STORAgE
 CAUTION: Disconnect heater 
from propane/LP supply cylinder.
1.  Do  not  store  heater  while  attached  to 
propane/LP cylinder. Close cylinder valve. 
Remove  the  hose/regulator  assembly 
from the propane/LP cylinder by turning 
the fuel gas connector nut clockwise.
2.  Storage  of  heater  inside  is  permissible 
only  if  the  cylinder  is  disconnected  and 
removed from the appliance.
3.  Store propane/LP cylinder in safe manner. 
Refer to Chapter 5 of Standard for Storage 
and Handling of Liquefied Petroleum Gases, 
ANSI/NFPA  58.
  Follow  all  local  codes. 
Cylinders  must  be  stored  outdoors  in  a 
well-ventilated area out of reach of children. 
Disconnected cylinders must have threaded 
valve plugs tightly installed, and must not be 
stored in a building, garage or any other en-
closed area. Never store cylinders near high 
heat,  open  flame,  or  where  temperatures 
exceed 100° F (38° C).
4.  Store in a dry, clean, and safe place.
MAINTENANCE
 WARNING: Never attempt to 
service  heater  while  it  is  con-
nected  to  propane/LP  supply, 
operating, or hot. Severe burns 
can  occur. Any  guard  or  other 
protective  device  removed  for 
servicing must be replaced prior 
to operating the heater.
1.  Keep  heater  clean.  Remove  any  debris 
from ventilation openings.
2.  Inspect  heater  before  each  use.  Check 
connections  for  leaks. Apply  mixture  of 
liquid  soap  and  water  to  connections. 
Bubbles  forming  show  a  leak  that  must 
be corrected. Correct all leaks at once.
3.  Inspect  hose/regulator  assembly  before 
each use. If hose is highly worn or cut, 
replace it immediately. At least annually, 
remove  hose/regulator  assembly  from 
heater to inspect entire length of hose.
4.  Spiders and insects can create a danger-
ous condition that may damage heater or 
make it unsafe. Keep burner area clean 
of all spiders, webs, or insects.
5.  Have heater inspected yearly by a quali-
fied service person.