CHECKING FOR PROPER VENTING 
After  completing  and  checking  electrical, 
gas and vent connections, follow the lighting 
instructions and allow the main burner to run 
for approximately 5 minutes. Hold a lighted 
match or cigarette near the top edge of fire-
place opening and play it along entire length 
of opening (see Figure 12). Proper venting 
should tend to draw the flame or smoke into 
the appliance. Improper venting or escaping 
of spillage of burned gas, is indicated when 
the match flickers or goes out. Smoke from a 
cigarette will also tend to disperse away from 
the appliance.
If  the  appliance  is  found  to  be  improperly 
venting,  shut  it  off  and  notify  your  installer 
or a qualified service agency to inspect the 
venting system.
VeNtING INstallatIoN
Continued
Check this area 
along entire top 
edge of fireplace 
opening. Smoke 
or flame should 
be drawn into 
appliance opening.
Figure 12 - Checking for Spillage
INstallatIoN
Figure 13 - Removing Front Refractory 
Access Panel
Figure 14 - Installing WRC Remote Receiver
Fireplace 
Receptacle
Remote 
Control 
Receiver
Extension Cord
Ignition 
Module Plug
NOTICE:  This  appliance  is 
equipped  with  a  vent  safety
shutoff  switch  which  will  shut
down the appliance in the case of
a venting problem. Do not bypass
the vent safety switch. If the appli-
ance should shut down, contact a
qualified installer, service agency
or your gas supplier to have the 
vent inspected before operating.
WALL SWITCH INSTALLATION
The installation of a wall switch allows you 
to activate the gas control valve and turn the 
fireplace on and off. The wall switch is to be 
connected to the incoming 120 volt regular 
household wiring that supplies electricity to 
the fireplace. Refer to wiring diagram in this 
manual on page 18.
OPTIONAL REMOTE CONTROL 
INSTALLATION (Model WRC)
Note:  If  using  optional  wireless  hand-held 
remote control, wall switch must be in the ON 
position to be operational. The remote control 
then becomes the switching mechanism for 
fireplace operation.
1.  Remove front refractory access panel by 
lifting up and angling out of firebox open-
ing (see Figure 13).
2.  The WRC model receiver does not require 
a  battery.  Receiver  can  be  installed  by 
plugging  the  short  extension  cord  into 
fireplace  receptacle.  Plug  receiver  unit 
into extension cord. Plug ignition module 
plug into receiver unit (see Figure 14).