FMI VM42EP(B,H) Benutzerhandbuch

Seite von 32
www.fmiproducts.com
108796-01U
12
3" Min.
(7.6 cm)
Side W
all 
Of Appliance 
GAS LINE HOOK-UP
WARNING: Gas line hookup
should  be  done  by  your  gas
supplier  or  a  qualified  service
person.
 WARNING: Before you pro-
ceed, make sure your gas supply
is OFF.
A manual shutoff valve has been included in 
the appliance’s gas supply system. You may 
consider installing an extra gas shutoff valve 
outside  appliance’s  enclosure  (check  with 
local codes) where it can be accessed more 
conveniently  with  a  key  through  a  wall  as 
shown in Figure 16.
In  conformance  with  local  codes,  route  a 
1/2" NPT gas line to appliance through hole 
in left side of firebox or sub-floor as shown 
in Figure 17.
CAUTION: Do not kink flex-
ible gas line.
3.  Activate  remote  handset  battery  by  re-
moving insulating tab on back of handset 
(see Figure 15). Battery is included pre-
installed.
4.  Once the battery is activated unit is ready 
to use.
5.  Replace front refractory access panel.
INstallatIoN
Continued
FMI  PRODUCTS,  LLC  recommends  that  a 
black  iron  gas  line  be  routed  from  the  gas 
source,  through  a  sediment  trap  (shown  in 
Figure  18)  and  into  appliance.  Once  con-
nected through appliance, a flexible gas line 
may be used for ease of installation to gas 
control valve (see Figure 19, page 13).
Before connecting black iron gas line to inside 
of appliance a sediment trap must be included 
outside appliance between gas line and gas 
shutoff valve. It must extend down 3" beyond 
center of pipe. Prepare incoming black iron 
gas  line  with  teflon  tape  or  pipe  joint  com-
pound (Check with local building codes).
Figure 16 - Manual Shutoff Valve 
Installation
Typical Exterior Wall Gas 
Shutoff Installation
Key
Extension
Shutoff 
Valve
Figure 17 - Routing Incoming Gas Line
A
1/2" NPT
Incoming Black
Iron Gas Line
7"
7"
Alternate Gas Supply
Through Sub-Floor
Incoming 
1/2" Gas Line 
Permitted by 
Local Codes
Sediment 
Trap (Not 
Supplied)
Figure 18 - Sediment Trap
Figure 15 - Installing Battery into Back of 
Handset
Pull to Remove 
Insulation Tab
Battery Cover
12 Volt Battery
Back of 
Handset
M36E(B,H),
M36EP(B,H
VM36E(B,H),
VM36EP(B,H)
M42E(B,H),
M42EP(B,H)
VM42E(B,H),
VM42EP(B,H)
A
5
/
8
" (21.9 cm)
10 
1
/
2
" (26.7 cm)