Appendix A: WPIM-SY Configuration
A-6 
Local Management User’s Guide
FRAME RELAY CONFIGURATION
This section provides instructions for connecting the WPIM-SY to a DDS (Digital Data System) 
circuit in a Frame Relay environment. Refer back to 
The line configuration information shown in 
WPIM-SY Physical Configuration
Begin the WPIM-SY Frame Relay configuration by accessing the WAN Configuration screen 
through Local Management. Proceed with the following steps:
1.
Use the arrow keys to highlight the [WPIM] field at the bottom of the screen. Press the 
SPACEBAR to select the WPIM being configured, then press ENTER.
2.
Use the arrow keys to highlight Mgr Type. Press the SPACEBAR to set the Mgr Type to 
FR PtoMP (Frame Relay Point to Multipoint) or FR PtoP (Frame Relay Point to Point), then 
press ENTER. These are the two settings for Frame Relay. Frame Relay Point to Point has one 
Interface per DLCI assigned when DLCIs are created by the Service Provider. In Frame Relay 
Point to Multipoint, there is one interface to multiple DLCI’S, and the DLCIs are dynamically 
learned. Backup can only be run on FR PtoP, not FR PtoMP.
3.
Use the arrow keys to highlight SYNC PORT TYPE. Press the SPACEBAR to set the Sync 
Port Type to V.35, RS422, RS232, or X.21.
4.
Use the arrow keys to highlight FORCE CTS True. Press the SPACEBAR to set to NO.
5.
Use the arrow keys to highlight FORCE DSR True. Press the SPACEBAR to set to NO.
6.
Use the arrow keys to highlight FORCE RTS True. Press the SPACEBAR to set to ENABLE.
7.
Use the arrow keys to highlight FORCE DTR True. Press the SPACEBAR to set to 
ENABLE.
Table A-2
Telco Configuration Information
 Configuration Information Required By User
Configuration Information Supplied By Service 
Provider
Clock Source
Telco provided or no clock source
Circuit Speed
64K, V.35, RS-422, RS-232, etc.