FRAME RELAY CONFIGURATION
Local Management User’s Guide
A-7 
8.
Use the arrow keys to highlight the SAVE command. Then press ENTER. The message “Save 
Done!” displays and Local Management saves the changes to memory and the device reboots. 
Local Management must be re-entered for any further configuration.
WPIM-SY Interface Configuration
 and 
proceed with the following steps.
1.
Access the WAN Interface Configuration screen by using the arrow keys to highlight the WAN 
Int Config
 option, then press ENTER.
2.
Use the arrow keys to highlight ProtMgrIface. Choose the interface to be configured.
3.
Use the arrow keys to highlight FR LMI. Press the SPACE bar to choose from ANSI 94, 
No LMI, T1.617-D, or Q.933-A, then press ENTER.
NOTE
Set FORCE CTS and FORCE DSR to YES only if the CSU/DSU does not support 
these flow control terms.
NOTE
The choice No LMI under FR LMI is a test mode only and must not be used in a 
practical application.