Enterasys csx400 Betriebsanweisung
Appendix B: WPIM-E1 Configuration
B-2
Local Management User’s Guide
WPIM-E1 Configuration Fields
specific to the WPIM-E1.
E1 Timeslot View —
Displays the status of the Timeslot Configuration Table. The selections for
this field toggle between Active and New. The Active setting displays current Timeslot
Configuration table settings. The default setting is Active. The New setting allows you to change
Timeslot Configuration table settings. The default setting for the Timeslot Configuration table is
all timeslots not assigned (000).
Configuration table settings. The default setting is Active. The New setting allows you to change
Timeslot Configuration table settings. The default setting for the Timeslot Configuration table is
all timeslots not assigned (000).
E1 Line Coding —
Displays the line coding for the physical E1 line. The selections toggle
between HDB3 and AMI. The default setting for this field is HDB3.
E1 Frame Type —
Displays the E1 Frame type. The selections toggle between E1 and E1-CRC.
The default setting for this field is E1-CRC.
E1 Tx Clock Source —
Displays the E1 Transmit Clock Source. The selections for this field
toggle between Loop-Timing (Extracted Line Data) and Local-Timing (Internal Clock). The
default setting for this field is Loop-Timing.
default setting for this field is Loop-Timing.
E1 Loop-back —
Network Loop-back is a testing procedure that segments the line and allows the
user to isolate faults. It is not used during normal operation. The selections for this field toggle
between None and Line-Loop. In Line-Loop all 32 channels are looped back to the E1 line.The
WPIM-E1 must be in Loop-Timing mode to use this option. The default setting is None.
between None and Line-Loop. In Line-Loop all 32 channels are looped back to the E1 line.The
WPIM-E1 must be in Loop-Timing mode to use this option. The default setting is None.
NOTE
The service provider determines the settings for the following fields. Consult the
service provider for the correct settings.
service provider for the correct settings.