Appendix B: WPIM-E1 Configuration
B-2
Local Management User’s Guide
WPIM-E1 Configuration Fields
specific to the WPIM-E1. 
E1 Timeslot View —
Displays the status of the Timeslot Configuration Table. The selections for 
this field toggle between Active and New. The Active setting displays current Timeslot 
Configuration table settings. The default setting is Active. The New setting allows you to change 
Timeslot Configuration table settings. The default setting for the Timeslot Configuration table is 
all timeslots not assigned (000).
E1 Line Coding —
Displays the line coding for the physical E1 line. The selections toggle 
between HDB3 and AMI. The default setting for this field is HDB3.
E1 Frame Type —
Displays the E1 Frame type. The selections toggle between E1 and E1-CRC. 
The default setting for this field is E1-CRC.
E1 Tx Clock Source —
Displays the E1 Transmit Clock Source. The selections for this field 
toggle between Loop-Timing (Extracted Line Data) and Local-Timing (Internal Clock). The 
default setting for this field is Loop-Timing.
E1 Loop-back —
Network Loop-back is a testing procedure that segments the line and allows the 
user to isolate faults. It is not used during normal operation. The selections for this field toggle 
between None and Line-Loop. In Line-Loop all 32 channels are looped back to the E1 line.The 
WPIM-E1 must be in Loop-Timing mode to use this option. The default setting is None.
NOTE
The service provider determines the settings for the following fields. Consult the 
service provider for the correct settings.