The WPIM Timeslot  Configuration Table
The WPIM Timeslot Configuration Table allows the user to configure the way in which the 
Cabletron WAN module uses the E1 line. The configuration table consists of 32 timeslots. Only 31 
of the timeslots are available for use, because the first timeslot is used by the device to transmit 
framing data. N/A (Not Available) always displays in Timeslot #1. You must assign each of the 
remaining 31 timeslots an Interface number (for example, 002 for an active Interface number or 
000 if the timeslot is not used). When you lease an entire E1 line, you can use all 31 timeslots (the 
full E1 bandwidth). If you lease only a fraction of the E1, the service provider tells you which 
timeslots to use.
You can utilize timeslots any way you choose. The WPIM-E1 supports Time Division 
Multiplexing (TDM) allowing demultiplexing of circuits (timeslots) within the public network. 
For example, if you have access to a full E1 (31 customer-usable timeslots), and you want to 
communicate with two other sites, your configuration might look like 
Figure B-2
Sample Timeslot Configuration
 shows a sample configuration for three sites. Of the 32 timeslots, Site #1 uses the first 
timeslot for transmitting framing data, 23 timeslots to communicate with Site #2 and the 
remaining 8 timeslots to communicate with Site #3. This configuration varies tremendously 
depending on how the service provider maps out the E1 timeslots. Your service provider will tell 
you which timeslots to configure.
NOTE
The WPIM-E1 always uses the first timeslot (Timeslot #1) to transmit framing data. A 
full E1 line with 32 timeslots has 31 customer-usable timeslots. 
SITE #1
SITE #2
Telco Cloud
32 Timeslots
(31 available to customer)
23 Timeslots
SITE #3
8 Timeslots
148402