Rotel RCC-1055 Benutzeranleitung

Seite von 14
13
English
Troubleshooting
Most difficulties in audio systems are the result 
of incorrect connections, or improper control 
settings. If you encounter problems, isolate the 
area of the difficulty, check the control settings, 
determine the cause of the fault and make the 
necessary changes. If you experience problems 
with the RCC-1055, refer to the suggestions 
for the following conditions:
Display Is Not Lit
The Disc, Track and Time indicators in the dis-
play should be lit whenever the power switch 
of the RCC-1055 is pushed in. If the display 
does not light, test the power outlet with another 
electrical device, such as a lamp. Be sure the 
power outlet being used is not controlled by 
a switch that has been turned off. 
Fuse Replacement
If another electrical device works when plugged 
into the power outlet, but the RCC-1055 display 
will not light when the power switch is pushed 
in, it indicates that the internal power fuse may 
have blown. If you believe this has happened, 
contact your authorized Rotel dealer to get the 
fuse replaced. 
Disc Does Not Play
If a disc does not begin playing when the Play 
button is pressed, open the disc tray and be 
sure the disc is loaded with the label side up. 
If a disc is properly loaded, inspect the playing 
side of the disc for contamination or damage. 
If the disc is dirty, clean it as described in the 
Handling Compact Discs section. If a disc is 
damaged it should be replaced.
No Sound
Check the input selector on the amplifier to be 
sure it is properly set. Check the tape monitor 
switches to be sure they are properly set. Check 
other signal sources to be sure the amplifier 
is operating properly. Finally check the audio 
cables between the RCC-1055 and the amplifier 
to be sure they are properly connected.
Sound Skips
If the sound from the RCC-1055 skips or jumps 
around, the disc may be defective or dirty. If 
the disc is clean, try another disc. If a problem 
persists it could be caused by vibrations reach-
ing the RCC-1055. Sound vibrations, especially 
from a subwoofer, can interfere with the laser 
reading a disc surface. Move the RCC-1055 to 
a more stable surface, or to a location farther 
away from the speakers.
Hum
Hum is caused by electrical interference from 
other devices. It is most often picked up by the 
audio signal cables. Use high-quality cables. 
Low quality cables often have inadequate 
shielding. Check to be sure the cables are 
solidly connected to both the RCC-1055 and 
the amplifier. Try moving the cables to a position 
farther away from other electrical components, 
especially power amplifiers which have large 
power transformers. Other devices that com-
monly cause interference are fluorescent lights 
and light dimmer controls.
Specifications
Frequency Response (±0.5dB) 
20-20,000 Hz
Signal to Noise Ratio 
>100 dB
Total Harmonic Distortion + Noise 
0.0045% @ 1kHz
Intermodulation Distortion 
0.0045% @ 1kHz
Dynamic Range 
>96 dB 
Channel Separation 
>98 dB @ 1kHz
Channel Balance  
± 0.5 dB
Phase Linearity  
± 0.5 degree
Speed Accuracy, Wow & Flutter  
Quartz Crystal Precision
Digital to Analog Converters  
18 bit equivalent, multi-level Delta-Sigma DAC with  
 
 
 
8x oversampling digital filter and HDCD
Maximum Audio Line Output/Impedance  
2 Volts/100 Ohms
Digital Output Level (coax)/Impedance 
0.5 Volt, Peak to Peak/75 Ohms
Power Requirements  
 
USA Version 
120 Volts, 60 Hz; 
 
European Version 
230 Volts, 50 Hz
Power Consumption 
15 Watts
Dimensions (W x H x D) 
432 x 121 x 410 mm 
 
 
 
17 x 4
3
/
4
 x 16
1
/
8
 inches
Panel Height 
109 mm / 4
9
/
32
 inches
Weight (net) 
7.8 kg, 17.2 lb.
All specifications are accurate at the time of printing.  