Fault Messages
255
15 COMM CHECK 
Yes
A message that appears 
in the CT emulation 
meaning the line is not 
active on a twinax 
interface.
Check cable connection.
15V CTL FAIL*
No
Controller voltage failure.
Contact your authorized service 
representative.
1
22 INVALID ADDR
Yes
Unit address not 
recognized by printer. 
(Twinax interface)
Ensure that printer address 
matches host setting.
23.5V CTL FAIL*
No
23.5 Volt Controller 
failed: a voltage failure on 
the controller board.
Contact your authorized service 
representative.
1
31 PAPER OUT
TIMEOUT
Yes
A timeout message is 
sent to the host if paper is 
not loaded 10 minutes 
after CLEAR was 
pressed to clear the 
paper out fault.
Load paper and run a print test. If 
the message reappears, contact 
your authorized service 
representative.
1
32 PAPER JAM 
TIMEOUT
Yes
A timeout message is 
sent to the host if no 
paper motion has 
occurred for 10 minutes 
after CLEAR was 
pressed to clear the jam 
fault.
Clear paper jam and reload paper. 
33 PLATEN OPEN
TIMEOUT
Yes
The forms thickness lever 
has been open for at 
least one minute.
Load paper, close the forms 
thickness lever, and press CLEAR.
34 RIBBON STALL 
TIMEOUT
Yes
In the CT emulation with 
a coax interface, the 
ribbon has not moved for 
10 minutes after CLEAR 
was pressed to clear the 
ribbon drive fault.
Reload the ribbon.
48V CIRCUIT*
See User Manual
No
Either the power supply is 
not generating a proper 
48 Volts or the controller 
board is not detecting a 
48 Volt output from the 
power supply board.
Contact your authorized service 
representative.
1
48V PWR FAIL*
No
Internal power failure.
Contact your authorized service 
representative.
1
Table 15. LCD Message Troubleshooting Table
Displayed Message
Can User 
Correct?
Explanation
Solution