Chapter 14  Troubleshooting
Over Temperature Condition
DLT-S4 Product Manual
128
Over Temperature Condition
14
The DLT-S4 tape drive has a thermal sensor located in the tape path. This 
sensor, which is used to accurately monitor the air temperature in the 
tape path, reacts in the following ways:
• TapeAlert occurs at 50 °C
• Shutdown occurs at 53 °C
SCSI status indicates the tape drive is in the over temperature condition. 
For more information, see the DLT-S4 Product Specification (81-81279-xx) 
and the DLT-S4 Interface Reference Guide (81-81281-xx)
Location
When the tape path temperature sensor 
detects an over temperature condition 
resulting in shutdown...
Not mounted in a 
library
The media rewinds, unloads, and ejects from the 
tape drive. 
Mounted in a 
library
The cartridge rewinds to BOT and unbuckles in 
preparation for unloading, but does not 
automatically eject.