Champion model i 66 Техническое Руководство

Seite von 6
70°F/39°C Rise – 24kW
Electric built-in booster (booster only) 
Minimum
Maximum
Supply Ckt.
Overcurrent
Elec.
Rated
Conductor
Protective
Specs.
Amps
Ampacity
Device
220/60/3
108
115
115
380/50/3
108
115
115
Volume crated: 
164 cu. ft./4.6 cu. m.
Shipping weight crated: 
950 lbs./431 kg.
Dimensions shown in inches and [millimeters]
Due to an ongoing value analysis program at Champion, specifications contained in this catalog are subject to change without notice.
Champion Industries, Inc., P. O. Box 4149, Winston-Salem, NC 27115  USA • 800/532-8591 • Fax: 336/661-1979 • www.championindustries.com
44" [1118] Single Tank with 
22" [559] Prewash High-Temperature
Rack Conveyor Dishwashing Machine
MODEL I 66 
SPECIFICATIONS
Capacity
Racks per hr.
208
Wash tank
US Gal. 21
Liters 79
Conveyor speed (ft/min.)
5.8
Motor Horsepower
Drive
1/6
Prewash
1
Wash
2
Water Consumption
Per hr. (max. use)
US Gal. 124
Liters 469
Per rack
US Gal. .60
Liters 2
Heating
Tank Heat, electric (kW)
15
Electric booster (built-in)
(kW supplied for 40°F rise)
15
Electric booster 
(kW supplied for 70°F rise)
24
Venting
Load end (minimum CFM)
200
Unload end (minimum CFM)
400
Standard 20" [508] x 20" [508] rack complement
Peg
2
Flat
1
Warning: 
Plumbing and electrical connections should be made by
qualified personnel who will observe all the applicable plumbing,
sanitary, safety codes and the National Electrical Code.
Note: 
Water Hammer Arrestor (meeting ASSE-1010 standard or
equivalent) to be supplied (by others) in common water supply line at
service connection.
Venting Notes: 
Fabricated duct size: 
3-7/8" x 15-7/8" (Outside dimensions) 
Utilities
Electrical
A Machine connection  
B Booster connection  
Hot Water
3/4" [19] NPT 140°F/60°C min. hot water connection.
(40°F/22°C rise booster) 
3/4" [19] NPT 110°F/49°C min. hot water connection.
(70°F/39°C rise booster)
Flow pressure 20-22 psi.
Drain 
1-1/2" [38] NPT machine connection. Maximum flow 15 gpm.
Vents
A Load end: 200 CFM @ 1/4" [6] S.P.
B Unload end: 400 CFM @ 1/4" [6] S.P. 
(With blower-dryer increase room ventilation by 600 CFM.)
Machine only
Minimum
Maximum
Supply Ckt.
Overcurrent
Elec.
Rated
Conductor
Protective
Specs.
Amps
Ampacity
Device
220/60/3
50
60
60
380/50/3
50
60
60
MACHINE CONNECTION
BOOSTER CONNECTION
40°F/22°C Rise – 15kW
Electric built-in booster (booster only)
Minimum
Maximum
Supply Ckt.
Overcurrent
Elec.
Rated
Conductor
Protective
Specs.
Amps
Ampacity
Device
220/60/3
86
110
110
380/50/3
86
110
110