Champion model i 66 Guida Specifiche
70°F/39°C Rise – 24kW
Electric built-in booster (booster only)
Minimum
Maximum
Supply Ckt.
Overcurrent
Elec.
Rated
Conductor
Protective
Specs.
Amps
Ampacity
Device
220/60/3
108
115
115
380/50/3
108
115
115
Volume crated:
164 cu. ft./4.6 cu. m.
Shipping weight crated:
950 lbs./431 kg.
Dimensions shown in inches and [millimeters]
Due to an ongoing value analysis program at Champion, specifications contained in this catalog are subject to change without notice.
Champion Industries, Inc., P. O. Box 4149, Winston-Salem, NC 27115 USA • 800/532-8591 • Fax: 336/661-1979 • www.championindustries.com
44" [1118] Single Tank with
22" [559] Prewash High-Temperature
Rack Conveyor Dishwashing Machine
22" [559] Prewash High-Temperature
Rack Conveyor Dishwashing Machine
MODEL I 66
SPECIFICATIONS
Capacity
Racks per hr.
208
Wash tank
US Gal. 21
Liters 79
Conveyor speed (ft/min.)
5.8
Motor Horsepower
Drive
1/6
Prewash
1
Wash
2
Water Consumption
Per hr. (max. use)
US Gal. 124
Liters 469
Per rack
US Gal. .60
Liters 2
Heating
Tank Heat, electric (kW)
15
Electric booster (built-in)
(kW supplied for 40°F rise)
15
Electric booster
(kW supplied for 70°F rise)
(kW supplied for 70°F rise)
24
Venting
Load end (minimum CFM)
200
Unload end (minimum CFM)
400
Standard 20" [508] x 20" [508] rack complement
Peg
2
Flat
1
Warning:
Plumbing and electrical connections should be made by
qualified personnel who will observe all the applicable plumbing,
sanitary, safety codes and the National Electrical Code.
sanitary, safety codes and the National Electrical Code.
Note:
Water Hammer Arrestor (meeting ASSE-1010 standard or
equivalent) to be supplied (by others) in common water supply line at
service connection.
service connection.
Venting Notes:
Fabricated duct size:
3-7/8" x 15-7/8" (Outside dimensions)
Utilities
1 Electrical
A Machine connection
B Booster connection
B Booster connection
2 Hot Water
3/4" [19] NPT 140°F/60°C min. hot water connection.
(40°F/22°C rise booster)
3/4" [19] NPT 110°F/49°C min. hot water connection.
(70°F/39°C rise booster)
Flow pressure 20-22 psi.
(40°F/22°C rise booster)
3/4" [19] NPT 110°F/49°C min. hot water connection.
(70°F/39°C rise booster)
Flow pressure 20-22 psi.
3 Drain
1-1/2" [38] NPT machine connection. Maximum flow 15 gpm.
4 Vents
A Load end: 200 CFM @ 1/4" [6] S.P.
B Unload end: 400 CFM @ 1/4" [6] S.P.
B Unload end: 400 CFM @ 1/4" [6] S.P.
(With blower-dryer increase room ventilation by 600 CFM.)
Machine only
Minimum
Maximum
Supply Ckt.
Overcurrent
Elec.
Rated
Conductor
Protective
Specs.
Amps
Ampacity
Device
220/60/3
50
60
60
380/50/3
50
60
60
MACHINE CONNECTION
BOOSTER CONNECTION
40°F/22°C Rise – 15kW
Electric built-in booster (booster only)
Minimum
Maximum
Supply Ckt.
Overcurrent
Elec.
Rated
Conductor
Protective
Specs.
Amps
Ampacity
Device
220/60/3
86
110
110
380/50/3
86
110
110