Enterasys csx400 Benutzerhandbuch

Seite von 275
Installation
66
CSX400 and CSX400-DC User’s Guide
3.
Using the four 6-32 x 1/4 inch flat-head screws, attach the rackmount brackets to the sides of 
the CSX400 as shown in 
.
Figure 17
 
Installing the Rackmount Brackets
4.
Position the CSX400 between the vertical frame members of the 19-inch rack.
5.
Fasten the CSX400 with mounting screws as shown in 
.
Bonding the Rackmount Brackets to the CSX400-DC
If the CSX400-DC is going to be mounted in a rack and needs to meet the GR-1089-CORE 
Section 9 bonding requirements, use the following instructions to install it into a 19-inch rack.
1.
Remove and discard the four cover screws (two from each side) located along the front edges 
of each side of the CSX400-DC.
2.
Remove the paint from around the area near the mounting holes on the left and right side of the 
cover of the CSX400-DC. See 
.
3.
Apply a thin layer of anti-oxidant to the surface where the paint was removed.
Screws (4)
Rackmount
Brackets (2)
2012_09