Enterasys csx200 Betriebsanweisung
WAN Configuration Using Local Management
150
CSX200 Family User’s Guide
4.
Use the arrow keys to highlight T1 Frame Type. Press the SPACEBAR to select ESF or D4,
then press ENTER.
then press ENTER.
5.
Use the arrow keys to highlight T1 Tx Clock Source. Press the SPACEBAR to select Local
(no clock source provided by telephone company) or Loop (clock source provided by telephone
company), then press ENTER.
(no clock source provided by telephone company) or Loop (clock source provided by telephone
company), then press ENTER.
6.
Use the arrow keys to highlight T1 Line Buildout (LBO). Press the SPACEBAR to select to
0 dB unless the service provider recommends another setting, then press ENTER.
0 dB unless the service provider recommends another setting, then press ENTER.
7.
Use the arrow keys to highlight the SAVE command, then press ENTER. The message “SAVE
DONE!” displays and Local Management saves the changes to memory.
DONE!” displays and Local Management saves the changes to memory.
8.
Access the WAN Interface Configuration screen by using the arrow keys to highlight the WAN
Int Config option, then press ENTER.
Int Config option, then press ENTER.
Frame Relay Interface Configuration
This screen is accessed through the WAN Physical Configuration screen. Proceed with the
following steps to configure the WAN Interface through Local Management.
following steps to configure the WAN Interface through Local Management.
1.
Set the Interface Number that is being used for the WAN connection by typing the same number
into the Interface Number field that was input into the Time Slots in the WAN Physical
Configuration screen, then press ENTER (refer to the NOTE above).
into the Interface Number field that was input into the Time Slots in the WAN Physical
Configuration screen, then press ENTER (refer to the NOTE above).
2.
Use the arrow keys to highlight Line Coding. Press the SPACEBAR to select NONE, then
press ENTER.
press ENTER.
3.
Use the arrow keys to highlight Active Protocol. Press the SPACEBAR to select FR, then
press ENTER.
press ENTER.
4.
Use the arrow keys to highlight FR LMP. Press the SPACEBAR to select T1.617-D, then press
ENTER.
ENTER.
5.
Use the arrow keys to highlight CKT_DCP Enable. Press the SPACEBAR to select ON, if you
want data compression enabled or OFF, if you do not, then press ENTER.
want data compression enabled or OFF, if you do not, then press ENTER.
6.
Use the arrow keys to highlight SAVE, then press ENTER. The message “SAVE DONE!”
displays and Local Management saves the changes to memory.
displays and Local Management saves the changes to memory.
NOTE
If you are using a Local clock source, set only one end of the circuit for Local, the other
end must be set for Loop.
end must be set for Loop.