Enterasys csx200 Betriebsanweisung

Seite von 261
WAN Configuration Using Local Management
CSX200 Family User’s Guide
149
The following information must be supplied to you by the service provider.
LMP type
:
ANSI T1.617 Annex D
The line configuration information shown in 
 must be supplied by the service provider.
Frame Relay Physical Configuration
Begin physical configuration by accessing the WAN Physical Configuration screen through Local 
Management. Proceed with the following steps:
1.
Use the arrow keys to highlight Time Slot View. Press the SPACEBAR to select New, then 
press ENTER. The cursor moves to Time Slot #1 of the Time Slot Configuration Table.
2.
Insert an interface number (refer to the NOTE below) into every Time Slot being used. Type 
the number, press ENTER, then use the arrow keys to highlight the next Time Slot field. Exit 
this field by using the arrow keys. The cursor automatically moves to the T1 Line Coding field.
3.
Use the arrow keys to highlight T1 Line Coding. Press the SPACEBAR to select B8ZS or 
AMI
, then press ENTER.
Table 16 Telco Configuration Information
Configuration Information 
Required by Customer
Information Supplied by Service 
Provider
Line Coding
B8ZS or AMI
Frame Type
ESF or D4
Clock Source
Loop Timing or Local Timing
DS-0s (Time Slots)
Time Slots being used for each end of 
the circuit
NOTES
The value assigned to the Time Slots is the interface being used for WAN 
communication. The available interface range is displayed on the WAN Physical 
Configuration screen (see 
). You may insert any of the available interface 
numbers into the Time Slots.
In the example shown in 
, the interface range for the CSX200 is 2–25. 
Although any of these values may be used, Cabletron Systems recommends using the 
first available interface number (in this example interface #2).
The following four steps are based on information supplied by the service provider. 
Consult the service provider for the correct settings.