After your CyberSWITCH has been configured, and before proceeding with normal system 
operation, it is necessary to verify that the system is functional. This chapter provides instructions 
for verifying the system hardware and system configuration. 
You only need to perform the verification procedures for the options that apply to your 
configuration. For example, if your configuration does not use SNMP, skip the SNMP verification 
section.
To perform the verification procedures, WAN lines must be available and ready to use. LAN 
attachment components must also be available and ready to use. 
During some of the procedures, we ask you to enter an administration console command. To enter 
these commands, you must have an active administration session. If you need instructions for 
starting an administration session, refer to 
Accessing the CyberSWITCH
.
Note:
At least one remote device is required to proceed with many of the verification procedures.
V
ERIFYING
 H
ARDWARE
 R
ESOURCES
 
ARE
 O
PERATIONAL
To verify the operation of the WAN and LAN hardware resources:
1.
At the system prompt, enter the 
dr
 command to display current system messages. At the 
administration console type:
dr
 
<return> 
2.
If you have enabled bridging, look for these LAN adapter initialization messages among the 
system messages: 
LAN Port <port #> is now in the LISTENING state 
LAN Port <port #> is now in the LEARNING state 
LAN Port <port #> is now in the FORWARDING state 
3.
If you have enabled IP routing, look for this LAN adapter initialization message among the 
system messages: 
[IP] IP router is initialized successfully
Note:
Other messages may also be displayed with the LAN adapter initialization messages. 
If these LAN adapter initialization messages are displayed, then the LAN adapter is operational. 
Proceed to the next section. 
If these LAN adapter initialization messages are NOT displayed, refer t
 in the 
Problem Diagnosis chapter.