Enterasys csx150 Betriebsanweisung
Small Office Remote Access Switch 337
S
YSTEM
V
ERIFICATION
Verifying Bridge is Initialized
If the system displays this message, then the test packet was transmitted correctly.
in
the Problem Diagnosis chapter.
V
ERIFYING
B
RIDGE
IS
I
NITIALIZED
To verify that bridging has initialized properly:
1.
Determine if the bridge is in the forwarding state by viewing the system messages. At the
administration console type:
administration console type:
dr
<return>
2.
The
dr
command displays the current system messages. Look for the following LAN adapter
messages among the system messages:
LAN Port <port #> is now in the LISTENING state
LAN Port <port #> is now in the LEARNING state
LAN Port <port #> is now in the FORWARDING state
Note:
Other messages may also be displayed with these LAN messages.
If you see these bridge initialization messages, then bridging is operational. If these bridge
initialization messages are NOT displayed, refer to
initialization messages are NOT displayed, refer to
in the Problem Diagnosis
chapter.
V
ERIFYING
IP R
OUTER
IS
I
NITIALIZED
To verify that IP routing has initialized properly:
1.
View the system messages. At the administration console type:
dr
<return>
2.
Look for the following IP message among the system messages:
[IP] IP router is initialized successfully
3.
For each IP interface that has been configured, the following interface initialization message
should be displayed among the system messages.
should be displayed among the system messages.
[IP] Network initialized successfully on ddd.ddd.ddd.ddd
Note:
Other messages may also be displayed with the IP router initialization messages.
If you see these IP router initialization messages, then the IP router is operational. If these IP
router initialization messages are NOT displayed, refer to
router initialization messages are NOT displayed, refer to
in the Problem
Diagnosis chapter.