Small Office Remote Access Switch      375
P
ROBLEM
 D
IAGNOSIS
IP Routing Over Interface Connections
encapsulations. Correct the IP Host or system configuration (through CFGEDIT) for 
encapsulation type. 
5.
Try to ping the Host from another device on the LAN. If this is also unsuccessful, this may 
indicate a problem with the Host.
6.
Verify that the hardware address (MAC address) for the IP Host in the system’s ARP cache is 
correct. If it is not correct, verify the configuration in the IP Host.
IP R
OUTING
 O
VER
 
A
 WAN I
NTERFACE
 C
ONNECTION
Problem:
The remote IP Host connected to a WAN interface does not receive a ping response from the 
CyberSWITCH WAN interface.
Action:
1.
Verify that the WAN connection is up. Use the 
mc
 console command to display the Connection 
Monitor display. Check for the connection. If the connection is up, continue with the next step.
If the connection is not up, refer to the section title
.
2.
Verify that the WAN interface is properly initialized. Use the 
ipnetif
 command (Manage 
Mode) to check for the proper WAN interface. If it exists, continue with the next step.
If the proper WAN interface does not exist, make corrections to the system configuration using 
CFGEDIT.
3.
Check that the IP address configured in the Device list for the IP Host device matches the 
address configured on the IP Host device. Make corrections to the CyberSWITCH’s 
configuration (using the 
iproute change 
Manage Mode command), or to the IP Host’s 
configuration, as required. 
Problem:
The remote IP Host connected to a WAN interface on the CyberSWITCH does not receive a ping 
response from the LAN interface.
Action:
1.
Verify that the remote IP Host can access the WAN interface of the CyberSWITCH. If the 
remote IP Host accesses the WAN interface successfully, then continue with the next step.
If the remote IP Host is not able to access the WAN interface, then refer to the preceding 
problem and associated actions.
2.
Verify that the LAN interface is properly configured by using the 
ipnetif
 command (a 
Manage Mode command). If the proper LAN interface exists, then continue with the next step.
If the proper LAN interface does not exist, use CFGEDIT to make corrections.
3.
Verify that the remote IP Host is initiating a call to the CyberSWITCH. Since the LAN interface 
has an IP address assigned with a different network number than the one for the remote IP