Enterasys D2G124-12P Installationsanweisungen

Seite von 76
1-Gigabit Ethernet and 100Base-FX Transceiver (SFP) Specifications
Enterasys D-Series Hardware Installation Guide A-5
MGBIC-02 Specifications (1000BASE-T)
MGBIC-LC03 Specifications (1000BASE-SX)
MGBIC-LC04 Specifications (100BASE-FX) 
Table A-8 MGBIC-02 Specifications
Item
Specification
Supported Cable
Type:
Maximum Length
Copper, Category 5 UTP
Up to 100 meters
Connector
RJ45
Data Rate
1 Gbps, IEEE 802.3:2000 compatible
1000BASE-T operation only
Automatic crossover detection
TX Output impedance
100 ohms, typical at all frequencies between 1 MHz and 125 MHz
RX Input impedance
100 ohms, typical at all frequencies between 1 MHz and 125 Hz
Table A-9 MGBIC-LC03 Optical Specifications
Item
62.5/125 µm MMF
50/125 µm MMF
Transmit Power (minimum)
-9.5 dBm
-9.5 dBm
Transmit Power (maximum)
-3 dBm
-3 dBm
Receive Sensitivity
-20 dBm
-20 dBm
Link Power Budget
1
 
(Multimode Only)
1. The maximum drive distance (up to 2 km) depends on the quality of the installed multimode fiber-optic cable
segment. Use the Link Power Budget to calculate the maximum cable length of the attached segment. The
Link Power Budget must not exceed those specified in this table. The MGBIC-LC03 input power must not
exceed -3 dBm. Otherwise, saturation could occur.
10.5 dB
10.5 dB
Table A-10 MGBIC-LC03 Operating Range
Item
Modal Bandwidth @ 1310 nm
Range
62.5 µm MMF
160 MHz/km
2,000 Meters
50 µm MMF
400 MHz/km
2,000 Meters
Table A-11 MGBIC-LC04 Optical Specifications
Item
62.5 µm MMF
50 µm MMF
Transmit Power (minimum)
-20 dBm
-23.5 dBm
Receive Sensitivity
-31 dBm
-31 dBm
Link Power Budget
1
 (Multimode Only)
1. The maximum drive distance (up to 2 km) depends on the quality of the installed multimode fiber-optic cable 
segment. Use the Link Power Budget to calculate the maximum cable length of the attached segment. The 
Link Power Budget must not exceed those specified in this table.
11 dBm
7.5 dBm