Enterasys D2G124-12P Installationsanweisungen

Seite von 76
Console Port Pinout Assignments
Enterasys D-Series Hardware Installation Guide A-7
MGBIC-LC09 Specifications (1000BASE-LX) 
Console Port Pinout Assignments
Refer back to “
” on page 2‐27 for information about console port 
pinout assignments.
Regulatory Compliance
This product meets the safety, electromagnetic compatibility (EMC), and environmental 
requirements listed in 
:
Table A-17 MGBIC-LC09 Optical Specifications
Item
62.5 µm MMF
50 µm MMF
10 µm SMF
Transmit Power (minimum)
-11.5 dBm
-11.5 dBm
-9.5 dBm
Receive Sensitivity
-20 dBm
-20 dBm
-20 dBm
Link Power Budget
8.5 dBm
8.5 dBm
10.5 dBm
Table A-18 MGBIC-LC09 Operating Range
Item
Modal Bandwidth @ 1300 nm
Range
62.5 µm MMF
500 MHz/km
2-550 Meters
50 µm MMF
400 MHz/km
2-550 Meters
50 µm MMF
500 MHz/km
2-550 Meters
10 µm SMF
N/A
2-10,000 Meters
Table A-19 Compliance Standards
Regulatory Compliance
Standard
Safety
UL 60950-1, FDA 21 CFR 1040.10 and 1040.11, CAN/CSA C22.2 
No. 60950-1, EN 60950-1, EN 60825-1, EN 60825-2, 
IEC 60950-1, 2006/95/EC (Low Voltage Directive)
Electromagnetic Compatibility (EMC)
FCC 47 CFR Part 15 (Class A), ICES-003 (Class A), EN 55022 
(Class A), EN 55024, EN 61000-3-2, EN 61000-3-3, AS/NZ 
CISPR-22 (Class A). VCCI V-3. CNS 13438 (BSMI), 2004/108/EC 
(EMC Directive)
Environmental
2002/95/EC (RoHS Directive), 2002/96/EC (WEEE Directive), 
Ministry of Information Order #39 (China RoHS)