Management Cable Pin Assignments
Fast Network 100 User Guide
Page A-5
A.4 MANAGEMENT CABLE PIN ASSIGNMENTS
For a PC running a Windows terminal connected to the RS232C Network 
Management Port on the front panel of the FN100, the following serial 
cable pin assignments are required to manage the FN100 using the Local 
Console Manager (LCM).
A.5 10BASE-T AND 100BASE-TX PIN ASSIGNMENTS
When connecting the FN100 to another device, use only RJ45 connectors 
on the cabling. An Ethernet twisted-pair link segment requires two pairs 
of wires. Each wire pair is identified by solid and striped colored wires. 
For example, one wire in the pair might be red and the other wire, red 
with white stripes.
Each port on the FN100 has built-in internal crossovers. If the network 
device you are connecting to the FN100 has a straight-through design, use 
a straight-through cable. See Section A.6, Straight-Through Wiring.
If the network device you are connecting to the FN100 has an internal 
crossover design, use an internal crossover cable. See Section A.7, 
Crossover Wiring
.
Table A-5
Serial Cable Pin Assignments
DB-9 (male) to 
FN100 (female)
PC DB9 
(female)
25-pin 
(female)
Pin 2 (Rx)
Pin 2
Pin 3
Pin 3 (Tx)
Pin 3
Pin 2
Pin 5 (Ground)
Pin 5
Pin 7