Enterasys b2g124-24 Benutzerhandbuch

Seite von 80
Connecting AC and RPS-SYS Power
SecureStack B2 Installation Guide  3-17
C2RPS-SYS Redundant Power System
If you are installing an optional redundant power system (C2RPS‐SYS), refer to the 
installation instructions supplied with the SecureStack RPS. The switch is connected to a 
C2RPS‐PSM using a C2RPS‐PSM Cable.
If you are installing the switch as a standalone switch, proceed to “
” on page 3‐18. If you are installing switches in a stack 
configuration, apply power to each switch in order, according to the procedure you use in 
Stack Initialization Overview
When you install and connect all the high‐speed stacking cables to the switches in the 
stack before applying power to the switches, the following occurs:
The switch that will manage (Manager) the stack is automatically established with all 
other switches established as Member switches in the stack. When the switches 
complete their initializations, one of the switches in the stack will illuminate its 
Manager LED, indicating that it is the stack Manager. The Manager LED on each 
Member switch will be off.
The hierarchy of the switches that will function as backup Manager is also determined 
in case the current Manager malfunctions, is powered down, or is disconnected from 
the stack.
The Console port on each Member switch is deactivated. Only the Console port on the 
Manager switch is active for out‐of band configuration to set the IP address, 
password, and other configuration settings.
Once you know which switch is the Manager, proceed to “
Caution: To prevent damaging the switch, DO NOTconnect a Power over 
Ethernet-compliant Redundant Power System (C2RPS-POE) to the redundant power 
supply connector. The switch is only compatible with the SecureStack C2RPS-SYS 
redundant power supply system. 
Precaución: No conecte una fuente de poder redundante (RPS) SecureStack C2 PoE 
(C2RPS-POE) al cable de corriente. De lo contrario, el dispositivo puede dañarse.