Enterasys 1805 Betriebsanweisung
36 ELS100-S24TX2M User Interface
ELS100-S24TX2M
Viewing the Current Port Configuration
The Port Information screen displays the port type, status, link state, and
flow control in use, as well as the communication speed and duplex mode.
To change any of the port settings, use the Port Configuration menu. The
parameters shown in the following figure and table are for the RJ-45 ports.
Figure 2-19. Port Information
SmartSTACK Local Management -- ELS100-S24TX2M
Port Information :
Unit 1 Port 1-12
Port Type Operational Link
FlowControl
Speed and
InUse Duplex InUse
-------------------------------------------------------------------------------------------------------
-------------------------------------------------------------------------------------------------------
1. 10/100TX
YES
DOWN -----------------
----------------
2. 10/100TX
YES
DOWN -----------------
----------------
3. 10/100TX
YES UP
802.3x
100-FULL
4. 10/100TX
YES
DOWN -----------------
----------------
5. 10/100TX
YES
DOWN -----------------
----------------
6. 10/100TX
YES
UP
NONE
100-HALF
7. 10/100TX
YES
UP
802.3x
100-FULL
8. 10/100TX YES UP
BACK_PRESSURE 10-FULL
9. 10/100TX
YES UP
BACK_PRESSURE 10-FULL
10. 10/100TX
YES
UP
BACK_PRESSURE 10-FULL
11. 10/100TX
YES
UP
BACK_PRESSURE 10-FULL
12. 10/100TX
YES
UP
BACK_PRESSURE 10-FULL
<OK> <PREV Unit> <NEXT UNIT> <PREV PAGE> <NEXT PAGE>
Use <TAB> or arrows keys to move. <Enter> to select.
Parameter
Description
Type
Shows port type as:
10/100TX : 10Base-T / 100Base-TX
100FX :
10/100TX : 10Base-T / 100Base-TX
100FX :
100Base-FX
1000SX :
1000Base-SX
1000LX
: 1000Base-LX
Operational
Shows if the port is functioning or not.
Link
Indicates if the port has a valid connection to an external device.
FlowControl InUse
Shows the flow control type in use. Flow control can eliminate
frame loss by “blocking” traffic from end stations connected
directly to the switch. Back pressure is used for half duplex and
IEEE 802.3x for full duplex. Note that flow control should not be
used if a port is connected to a hub.
frame loss by “blocking” traffic from end stations connected
directly to the switch. Back pressure is used for half duplex and
IEEE 802.3x for full duplex. Note that flow control should not be
used if a port is connected to a hub.
Speed and
DuplexInUse
DuplexInUse
Displays the current port speed and duplex mode used.