36  ELS100-S24TX2M User Interface
ELS100-S24TX2M
Viewing the Current Port Configuration
The Port Information screen displays the port type, status, link state, and 
flow control in use, as well as the communication speed and duplex mode. 
To change any of the port settings, use the Port Configuration menu. The 
parameters shown in the following figure and table are for the RJ-45 ports.
Figure 2-19.  Port Information
SmartSTACK Local Management -- ELS100-S24TX2M
Port Information :
 Unit 1 Port 1-12
Port       Type      Operational  Link    
FlowControl    
Speed and
                                                                         InUse                        Duplex InUse
-------------------------------------------------------------------------------------------------------
1.     10/100TX  
YES
DOWN     ----------------- 
----------------
2.     10/100TX   
YES 
DOWN     ----------------- 
----------------
3.     10/100TX   
YES       UP      
802.3x         
100-FULL
4.     10/100TX   
YES 
DOWN     ----------------- 
----------------
5.     10/100TX   
YES 
DOWN     ----------------- 
----------------
6.     10/100TX   
YES 
UP      
NONE           
100-HALF
7.     10/100TX   
YES 
UP
802.3x         
100-FULL
8.     10/100TX     YES       UP      
BACK_PRESSURE  10-FULL
9.     10/100TX   
YES       UP      
BACK_PRESSURE  10-FULL
    10.     10/100TX
YES 
UP      
BACK_PRESSURE  10-FULL
11.     10/100TX  
YES 
UP      
BACK_PRESSURE  10-FULL
12.     10/100TX   
YES 
UP      
BACK_PRESSURE  10-FULL
<OK> <PREV Unit> <NEXT UNIT> <PREV PAGE> <NEXT PAGE>
Use <TAB> or arrows keys to move. <Enter> to select.
Parameter
Description
Type
Shows port type as:
10/100TX  : 10Base-T / 100Base-TX
100FX : 
100Base-FX
1000SX : 
1000Base-SX
1000LX
: 1000Base-LX
Operational
Shows  if the port is functioning or not.
Link
Indicates  if the port has a valid  connection to an external device.
FlowControl InUse
Shows the flow control type in use. Flow control can eliminate 
frame loss by “blocking” traffic from end stations connected 
directly to the switch. Back pressure is used  for half duplex and 
IEEE 802.3x for full duplex. Note that flow control should not be 
used if a port is connected to a hub.
Speed and 
DuplexInUse
Displays the current port speed and duplex mode used.