threshold (in either direction), an alarm is generated.
::= { rlpThreshTable.1.6}
rlpThreshRtxFramesPerSec
SYNTAX:
INTEGER (
0–65535
)
ACCESS:
Read only
STATUS:
Mandatory
DESCRIPTION:Per-second threshold for the statistic
, which is the number of frames
retransmitted on the RLP. (This corresponds to the
database parameter
database parameter
Retransmitted frames per sec
.) If the
measured value for the statistic crosses the threshold (in
either direction), an alarm is generated.
either direction), an alarm is generated.
::= { rlpThreshTable.1.7}
portThreshTable (statThresh.2)
portThreshRlpIndex
SYNTAX:
INTEGER (
1–8
, which correspond to actual RLP numbers
0–7
)
ACCESS:
Read only
STATUS:
Mandatory
DESCRIPTION:RLP number.
::= { portThreshTable.1.1}
::= { portThreshTable.1.1}
portThreshIndex
SYNTAX:
INTEGER (
1–8
, which correspond to physical port
numbers
0–7
)
ACCESS:
Read only
STATUS:
Mandatory
DESCRIPTION:Port number.
::= { portThreshTable.1.2}
::= { portThreshTable.1.2}
portThreshRxFramesPerSec
SYNTAX:
INTEGER (
0–65535
)
ACCESS:
Read only
STATUS:
Mandatory
,
which is the number of frames received on the port. (This
corresponds to the database parameter
corresponds to the database parameter
Received frames/