Enterasys 6000 Verweisanleitung

Seite von 238
134
Cabletron  Relay Access Products
Sec
.) If the measured value for the statistic crosses the 
threshold (in either direction), an alarm is generated.
::= { portThreshTable.1.3}
portThreshTxFramesPerSec
SYNTAX:
INTEGER (
0–65535
)
ACCESS:
Read only
STATUS:
Mandatory
DESCRIPTION:Per-second threshold for the statistic 
which is the number of frames transmitted on the port. 
(This corresponds to the database parameter 
Transmitted 
frames/Sec
.) If the measured value for the statistic crosses 
the threshold (in either direction), an alarm is generated.
::= { portThreshTable.1.4}
portThreshRtxFramesPerSec
SYNTAX:
INTEGER (
0–65535
)
ACCESS:
Read only
STATUS:
Mandatory
DESCRIPTION:Per-second threshold for the statistic 
, which is the number of frames 
retransmitted on the port. (This corresponds to the database 
parameter 
Retran frames/Sec
.) If the measured value for 
the statistic crosses the threshold (in either direction), an 
alarm is generated.
::= { portThreshTable.1.5}
portThreshFCSErrPerSec
SYNTAX:
INTEGER (
0–65535
)
ACCESS:
Read only
STATUS:
Mandatory
DESCRIPTION:Per-second threshold for the statistic 
which is the number of Frame Check Sequence errors on 
the port. (This corresponds to the database parameter 
FCS 
errors/Sec
.) If the measured value for the statistic crosses 
the threshold (in either direction), an alarm is generated.
::= { portThreshTable.1.6}