Enterasys 6000 Verweisanleitung
MI B Ref erence
183
STATUS:
current
DESCRIPTION:Controls the support for transmission and receipt of SIM
and RIM control frames for this link station. The value of
this object controls the setting of the transmit-receive
capability sent in the XID field.
this object controls the setting of the transmit-receive
capability sent in the XID field.
DEFVAL:
{
1
(No) }
::= { sdlcLsAdminTable.1.17}
sdlcLSAdminXmitRcvCap
SYNTAX:
INTEGER {
1
(twa),
2
(tws)}
MAX-ACCESS: read-create
STATUS:
STATUS:
current
DESCRIPTION:Controls the transmit-receive capabilities for this SDLC
link station. The value of this object establishes the value
of the transmit-receive capability indicator sent in the XID
image to the adjacent link station.
of the transmit-receive capability indicator sent in the XID
image to the adjacent link station.
DEFVAL:
{
1
(twa) }
::= { sdlcLsAdminTable.1.18}
sdlcLSAdminRowStatus
SYNTAX:
RowStatus
MAX-ACCESS: read-create
STATUS:
STATUS:
current
DESCRIPTION:Used by a management station to create or delete the
row entry in
sdlcLSAdminTable
following the RowStatus
textual convention. On successful creation of the row, an
agent automatically creates a corresponding entry in the
agent automatically creates a corresponding entry in the
sdlcLSOperTable
with
sdlcLSOperState
equal to
’discontacted’ (
1
).
::= { sdlcLsAdminTable.1.19}
sdlcLSOperTable (sdlcLSGroup.2)
sdlcLSOperName
SYNTAX:
DisplayString (1–10 characters)
MAX-ACCESS: Read only
STATUS:
STATUS:
current
DESCRIPTION:Octet string that defines the name of the remote SDLC link
station. This field is received in the XID3 control vector
0x0E
, type
0xF7
.
::= { sdlcLSOperTable.1.1}