Cabletron Relay Access Products
sdlcLSOperRole
SYNTAX:
INTEGER {
1
(Primary),
2
(Secondary),
3
(Undefined)}
MAX-ACCESS: Read only
STATUS:
STATUS:
current
DESCRIPTION:Current role assumed by the link station. The value of
sdlcLSOperRole
is undefined(
3
) whenever the link station
role has not yet been established by the mode-setting
command.
command.
::= { sdlcLSOperTable.1.2}
sdlcLSOperState
SYNTAX:
INTEGER {
1
(discontacted),
2
(contactPending),
3
(contacted),
4
(discontactPending)}
MAX-ACCESS: Read only
STATUS:
STATUS:
current
DESCRIPTION:Operational state of the SDLC link station. The managed
system will attempt to keep this value consistent with the
administered state,
administered state,
sdlcLSAdminState
.
::= { sdlcLSOperTable.1.3}
sdlcLSOperMAXDATASend
SYNTAX:
Integer32
MAX-ACCESS: Read only
STATUS:
STATUS:
current
DESCRIPTION:Actual maximum PDU size the local link station can send
to the adjacent link station. This object is established from
the value received in the XID from the adjacent link
station. If no XID is received, then this value is implemen-
tation dependent (for instance, it could be the value of
the value received in the XID from the adjacent link
station. If no XID is received, then this value is implemen-
tation dependent (for instance, it could be the value of
sdlcLSAdminMAXDATASend
). This value includes the
Transmission Header (TH) and the Request Header (RH).
::= { sdlcLSOperTable.1.14}
sdlcLSOperREPLYTO
SYNTAX:
TimeInterval (in 1/100ths of a second)
MAX-ACCESS: Read only
STATUS:
STATUS:
current
DESCRIPTION:Current reply timeout for an SDLC link station. If the link
station does not receive a response to a poll or message
before the specified time expires then the appropriate error
before the specified time expires then the appropriate error