Unlinking 
 
There are three ways to unlink an imager from a cradle: 
 
 
 
 
 
      Force imager to disconnect and sleep 
 
1. 
Scan the “Force imager to disconnect and sleep” 
barcode
 – Reading the unlink barcode above while the 
imager is in range of the cradle will break the link 
between the two devices and allow another imager to 
link to the cradle. It will also have the imager in Deep 
Sleep Mode
. If the barcode is read when the imager is 
out of range of its linked cradle, the imager will unlink, 
but the cradle will remain linked to the imager and will 
not allow another imager to be linked to it. In this case, 
you may perform the item 2 below to link another 
imager. 
 
2. 
Scan the Link Label and put on the original cradle – 
If the cradle is linked with an imager and the original pair 
was stopped by out of range of the cradle or out of 
battery of the imager, scan the link label of the cradle 
with a new imager and then put on the cradle, the cradle 
will drop the original pair and establish a new link with 
the new imager. 
 
3. 
Scan the Link Label on an alternate cradle – 
Scanning the link label on a cradle will drop the link 
between the original pair and establish a link between 
the imager and new cradle. If the new link is performed 
within range of the old cradle, it is free to establish a link 
to the next imager that reads its link label. If it is done 
outside of the range of the old cradle, it retains its old 
link and will not allow a new imager to link to it until a 
new imager scan the link label and put on the cradle. 